Mounting
Lift the deflection head and turn in the desired approach direction.
Tighten the 2 screws on the deflection head with 0.7–0.9Nm.
Close unused opening with the dust cover.
6.2
Mounting the Safety Switch
Prerequisites for mounting:
• deflection head has been set
• fully assembled
Select the mounting location so that the following conditions are satisfied:
• Safety Switch and actuator can be well matched to one another mechanically and
can be permanently mounted
• accessible to qualified personnel for testing and replacement
• difficult to access by operating personnel while the protective device is open