Wiring examples of sink-type pulse generator

The following figures show wiring to the sink-type pulse generator. The examples show wiring that connects the pulse
generator only to CH1. In the examples, the voltage of the external power supply connected to the pulse generator is 24VDC.
Ground the FG terminal of the power supply module.
Transistor output
Pulse input module
Contact output
Pulse input module
6 INSTALLATION AND WIRING
28
6.2 External Wiring
Shielded
twisted pair cable
CH1 V+
CH1 V-
FG
+
24VDC
power supply
-
Shielded
twisted pair cable
CH1 V+
CH1 V-
FG
+
+
24VDC
power supply
-
-
Pulse generator
+24V
GND
Pulse generator
+24V
GND