Routine Cleaning; Preventative Maintenance - Stoelting IntelliTec M202 series Operator's Manual

Table of Contents

Advertisement

Figure 3-7 Install Front Wear Bushing
E.
Lubricate the inside and outside of the front wear
bushing with Petrol Gel and install it onto the
auger (Fig. 3-7).
F.
Install the large o-ring onto the faceplate and
install the faceplate onto the machine.
G.
Install slide, hopper cover and drain tray.

3.11 ROUTINE CLEANING

To remove spilled or dried mix from the machine exterior,
wash in the direction of the fi nish with warm soapy water
and wipe dry. Do not use highly abrasive materials, as
they will mar the fi nish.

3.12 PREVENTATIVE MAINTENANCE

It is recommended that a maintenance schedule be fol-
lowed to keep the machine clean and operating properly.
A. DAILY
Disassemble and Clean
The frequency of cleaning the machine and parts must
comply with local health regulations. Refer to the previous
sections for proper disassembly and cleaning instructions.
Lubricate Front Wearguard
Petrol Gel sanitary lubricant or equivalent must be used
when lubrication of parts is specifi ed. Apply a thin fi lm of
sanitary lubricant to the inside and outside of the front
wearguard.
Part
C-2000-50 Spring
C-2000-51 Blade
SL-0010
149014
625174
Owner's Manual #513666
Description
Seal - Beater Shaft
Bushing - Front Auger Support
O-Ring - Front Door
Figure 3-8 Parts Replacement Schedule
Inspect Parts
Inspection for worn or broken parts should be made each
time the machine is disassembled. All worn or broken
parts should be replaced to ensure safety to both the
operator and the customer and to maintain good machine
performance and a quality.
Lubricate Back End of the Auger
Lubricate the rear of the auger with a small amount of
spline lubricant.
B. WEEKLY
Clean Inside Of Machine
Remove all side panels and clean the inside of the ma-
chine. Wipe any custard that may have dripped onto the
inner panels with a damp soapy towel. Wash the drain tray.
C. MONTHLY
Clean Condenser Coils (And Filters If Applicable)
The coils on the hopper, dipping cabinet and remote con-
denser need to be cleaned to ensure proper airfl ow. Use
compressed air to clean the condensers. Blow the air in
the opposite direction of the normal airfl ow.
C. QUARTERLY
Replace Barrel Parts According To Schedule
Follow the Parts Replacement Schedule below to keep
the machine operating properly.
D. ANNUALLY
High voltage will shock, burn or cause death. Turn
off and lock out main power disconnect before
servicing. Do not operate machine with panels
removed.
Replace Barrel Parts
Follow the Parts Replacement Schedule below to keep
the machine operating properly.
3 Months Annually Qty per Barrel
X
X
X
X
X
14
WARNING
10
10
1
1
1
M202B Model Machines

Advertisement

Table of Contents
loading

This manual is also suitable for:

Intellitec m202b a/c remoteIntellitec m202b a/cIntellitec m202b w/c

Table of Contents