FAULT CODES

If all battery type selection lights are flashing simultaneously please see troubleshooting guide below.
MODE
GEL
There are error codes that may be displayed. These will be displayed in the
following way:
S1
Stage LED
LED
Solar input
high voltage
Solar input
reverse
Alternator
high voltage
Alternator
input reverse
Output
fault mode
NOTE: To activate the Charger when the auxiliary battery is below 9V, connect a set of jumper cables from a fully
charged battery (such as your start battery) to your auxiliary battery and check that the charging LED on the DC-
DC charger flashes after minimum cut in voltage is reached and 120 second delay has passed. You can then
remove the jumper cables.
BATTERY TYPE
AGM
WET
CALCIUM
S2
S3
S4
LED
LED
LED
Over voltage is detected
Overvoltage is detected
Overvoltage is detected
LITHIUM
Cause
at solar input
Solar input is reverse
connected
at alternator
Alternator input is
reverse connected
Output battery is
reverse connected
at output
Output open circuit
or dead battery
KickAss constantly updates
frequently asked questions,
troubleshooting, videos and
specifications, please visit:
www.kickass.com.au
for the most up to date
information.
13
Remedy
Check solar panel
open circuit voltage
Check solar input
connection
Check vehicle
battery voltage
Check alternator
input connection
Check output
cable connection
Check auxiliary
battery voltage
Check auxiliary battery
voltage & cable connections