UNDERSTANDING SOLAR, ALTERNATOR
& CHARGING LIGHTS
SOLAR
ALTERNATOR
CHARGING
• Alternator has priority over solar therefore, if solar and alternator LED are solid, then alternator is charging
• 120 sec delay between cut-in voltage being reached, and charging beginning & 120 sec delay before
disconnecting when under cut-in voltage.
NOTE
Alternator LED indicator
Alternator voltage 12V
0-8 Volts
9-12.8 Volts
12.8-13.3 Volts
13.4 Volts
Alternator LED indicator with ignition override wire connected
Alternator voltage 12V
0-8 Volts
9-11.8 Volts
11.9-12.1 Volts
12.2 Volts
Solar LED status
Solar voltage
0-8.9 Volts
9 Volts
Solid on - cut-in voltage reached.
(see table below for other indications)
Solid on - cut-in voltage reached.
(see table below for other indications)
Charging light will flash when unit is charging.
Alternator voltage 24V
Alternator LED
12-16 Volts
OFF
18-25.6 Volts
Flash 1 sec on 5 sec off
25.6-26.6 Volts
Flash 1 sec on 1 sec off
26.8 Volts
Solid on
Alternator voltage 24V
Alternator LED
12-16 Volts
OFF
18-23.6 Volts
Flash 1 sec on 5 sec off
23.8-24.2 Volts
Flash 1 sec on 1 sec off
24.4 Volts
Solid on
Solar LED
OFF
Solid on
Status
Under cut-in voltage
Cut-in voltage reached, charging will begin after 10 sec
delay (please note alternator has priority over solar)
12
Status
Under cut-in voltage
Under cut-in voltage
Under cut-in voltage
Cut-in voltage reached, charging
will start after 120 sec delay
Status
Under cut-in voltage
Under cut-in voltage
Under cut-in voltage
Cut-in voltage reached, charging
will start after 120 sec delay