Summary of Contents for AGS Merlin 1000Si

  • Page 1 Merlin 1000Si Gas Utility Controller User & Installation Manual Gas Safety Products Merlin 1000Si Gas Utility Controller Installation, operating and maintenance Rev: 02 Date: 08-01-18...
  • Page 2 Merlin 1000Si Gas Utility Controller User & Installation Manual Table of contents General information ................3 Installation ................... 3 Panel Mounting....................3 Power Supply....................3 Gas solenoid valve..................3 BMS Connections................... 3 Timeout Facility....................3 Remote emergency shut off buttons.
  • Page 3: General Information

    Auto-shut down timeout is selectable. There are two dip-switches located on the inside facia of the Merlin 1000Si labelled “Time1” and “Time2”. They are factory set in the ‘off’ position for a 2 hour timeout. On installation, they can be switched to the ‘on’ position to select required timeout.
  • Page 4: Operation Instructions

    Power LED When the system is connected to the mains supply, the Red LED of the AGS Logo located in the bottom right corner of the panel will illuminate. When no power is present, this LED will not light up.
  • Page 5: Using The Emergency Shut Off

    The Fan Switch provides the facility to turn on the fan(s) when the key switch on the Merlin 1000Si is in the on position and turn the power off to the fan(s) when the key switch on the Merlin 1000Si is in the off position.
  • Page 6: Si Wiring Diagram

    Merlin 1000Si Gas Utility Controller User & Installation Manual 1000Si Wiring Diagram 12 13 Detector Monitor L N E Gas Valve Stop 1. Mains Input 100-240VAC Single Phase. 2. Gas Solenoid Valve Power Output, 100-240VAC, Max 3A. 3. Electric Contactor, this is disabled on this system.
  • Page 7 Merlin 1000Si Gas Utility Controller User & Installation Manual INFORMATION ON WASTE DISPOSAL FOR CONSUMERS OF ELECTRICAL & ELECTRONIC EQUIPMENT When this product has reached the end of its life it must be treated as Waste Electrical & Electronics Equipment (WEEE). Any WEEE marked products must not be mixed with general household waste, but kept separate for the treatment, recovery and recycling of the materials used.