Testec TT-HVP 40 User Manual

Testec TT-HVP 40 User Manual

High voltage probe

Advertisement

Quick Links

Safety Precautions
This high voltage probe must only be used by personnel who are trained, experienced, or
otherwise qualified to recognize hazardous situations and who are trained in the safety
precautions that are necessary to avoid possible injury when using such a device.
Do not work alone when working with high voltage circuits
For your own safety, inspect the probes for cracks and frayed or broken leads before each use. If
defects are noted, DO NOT use the probe.
Hands, shoes, floor and work bench must be dry. Avoid making measurements under humid,
damp or other environmental conditions that might effect the safety of the measurement situation.
It is advisable to turn the high voltage source off before connecting or disconnecting the probe.
The probe body should be kept clean and free of any conductive contamination. Refer to the
section on cleaning.
Operation
Connect the plugs to the volts [Hi] and com [Lo] terminals of your voltmeter
Select the desired voltage function and range; do not use autoranging
Whenever possible, turn the high voltage source off before making any connections
Connect the divider probe common lead (alligator clip) to a good earth ground or reliable chassis
ground
Do not attempt to take measurements from sources where the chassis or return lead is not
Warning
grounded
The ground lead is critical to the safe operation of the probe. Failure to make this connection when
making high voltage measurements may result in personal injury or damage to the probe or volt-
meter. This connection must always be made BEFORE the probe tip comes in contact with the
high voltage and must not be removed until the probe tip has been removed from the high voltage
source.
Do not connect the ground clip lead to the high voltage source for any reason.
Before turning the high voltage on, make sure that no part of your body is in contact with the
device under test.
Measure the voltage remembering that the voltage being measured is 1000 times greater than the
voltmeter reading.
Turn the high voltage off.
Disconnect the probe tip from the high voltage source BEFORE removing the ground clip lead.
Cleaning
Clean only the exterior probe body and cables. Use a soft cotton cloth lightly moistened with a mild
solution of detergent and water. Do not allow any portion of the probe to be submerged at any
time.
Dry the probe thoroughly before attempting to make voltage measurements.
Do not subject the probe to solvents or solvent fumes as these can cause deterioration of the
probe body and cables.
TesTec elektronik GmbH
TESTEC Elektronik GmbH
Bornheimer Landstr. 32-34
Westerbachstr. 58
60316 Frankfurt
D-60489 Frankfurt
®
Phone: +49-(0)69-943335-0
Phone : +49-(0)69-943335-0
Fax:
Fax
+49-(0)69-94333555
: +49-(0)69-94333555
Internet:
Internet:
www.testec.de
www.testec.de
Bedienungsanleitung
TESTEC Hochspannungs-Tastkopf TT-HVP 40
Bedienungsanleitung
TESTEC Hochspannungs-Tastkopf TT-HVP 40
Warnung
Dieser Hochspannungs-Tastkopf wurde so entwickelt, dass der Benutzer bei ordnungsgemäßer
Benutzung vor einem versehentlichen Kontakt mit der Hochspannung geschützt wird. Vor Gebrauch
des Tastkopf ist diese Bedienungsanleitung zu lesen und ihr Inhalt zur Kenntnis zu nehmen. Eine
unsachgemäße Vorgehensweise oder die inkorrekte Analyse einer Messsituation kann zu schweren
Unfällen führen.
User's Guide
Warnung
Dieser Hochspannungs-Tastkopf wurde so entwickelt, dass der Benutzer bei ordnungsgemäßer
Agilent Technologies 34136A High Voltage Probe
Allgemeine Informationen
Benutzung vor einem versehentlichen Kontakt mit der Hochspannung geschützt wird. Vor Gebrauch
des Tastkopf ist diese Bedienungsanleitung zu lesen und ihr Inhalt zur Kenntnis zu nehmen. Eine
Der Testec Hochspannungs-Tastkopf TT-HVP 40 ist ein Zubehörteil für den Einsatz bei analogen oder
unsachgemäße Vorgehensweise oder die inkorrekte Analyse einer Messsituation kann zu schweren
digitalen Multimetern mit einem Eingangswiderstand von 10 MΩ (± 1 %). Das Testec-Modell
Unfällen führen.
TT-HVP 40 ist ein 1000:1-Teiler, der die Messkapazität eines Voltmeters auf 40 kV DC/28 kV RMS AC
erweitert.
Allgemeine Informationen
Der Testec Hochspannungs-Tastkopf TT-HVP 40 ist ein Zubehörteil für den Einsatz bei analogen oder
Spezifikationen
digitalen Multimetern mit einem Eingangswiderstand von 10 MΩ (± 1 %). Das Testec-Modell
TT-HVP 40 ist ein 1000:1-Teiler, der die Messkapazität eines Voltmeters auf 40 kV DC/28 kV RMS AC
Maximale Eingangsspannung CAT I
erweitert.
W A R N I N G
This high voltage probe is designed to prevent accidental shock to the operator when properly
Gleichspannung: 40 kV
used. This operating note must be read and understood prior to using the probe. Improper
Wechselspannung: (0 bis 300 Hz) 28 kV RMS
Spezifikationen
procedures or incorrect analysis of the measurement situation can result in serious shock.
Genauigkeit
Maximale Eingangsspannung CAT I
General Information
Gleichspannung: ± 2 % (1 kV bis 20 kV)
Gleichspannung: 40 kV
The Agilent Technologies 34136A High Voltage Probe is an accessory to be used with analog or digital
Wechselspannung: (0 bis 300 Hz) 28 kV RMS
± 3 % (20 kV bis 40 kV)
multimeters having an input resistance of 10 M Ω ( ±1%). The Agilent Technologies Model 34136A
is a 1000:1 divider which extends a voltmeter's measurement capability to
Genauigkeit
40 kV dc/ 28 kV rms ac.
Gleichspannung: ± 2 % (1 kV bis 20 kV)
± 3 % (20 kV bis 40 kV)
Specifications
Andere Charakteristika
Maximum Input Voltage
Eingangswiderstand
DC Voltage: 40kV
AC Voltage: (0 to 300 Hz) 28 kV RMS
1000 MΩ
Andere Charakteristika
Accuracy
DC volts: ±2% (1 kV to 20 kV)
Eingangswiderstand
Kabellänge
±3% (20 kV to 40 kV)
1000 MΩ
1 Meter
Pollution Degree 2
Kabellänge
Other Characteristics
Höhe
1 Meter
Bis 4.6000 Meter (15.000 Fuß)
Input Resistance
Höhe
1000 MΩ
Genauigkeit
Bis 4.6000 Meter (15.000 Fuß)
Cable Length:
Wechselspannung: 5 % bei 60 Hz
1 meter
Genauigkeit
Altitude:
Wechselspannung: 5 % bei 60 Hz
Up to 4,600 meters (15,000 ft)
Accuracy
Der Wechselspannungs-Ausgang fällt mit
AC Volts: 5% at 60 Hz
der Frequenz auf –3dB bei 300 Hz ab. Die
Der Wechselspannungs-Ausgang fällt mit
AC output derates with frequency to
Grafik rechts zeigt die typische Genauigkeit
der Frequenz auf –3dB bei 300 Hz ab. Die
-3db at 300 Hz. The graph at the right
bei Wechselspannung.
shows typical AC accuracy.
Grafik rechts zeigt die typische Genauigkeit
Actual AC accuracy varies with the
bei Wechselspannung.
Die tatsächliche Genauigkeit bei Wechsel-
amount of shunted input capacitance.
spannung variiert mit der Menge der
Die tatsächliche Genauigkeit bei Wechsel-
spannung variiert mit der Menge der
abgegriffenen Eingangskapazität.
abgegriffenen Eingangskapazität.
sa
Temperatur-Koeffizient
Weniger als 200ppm/°C
Genauigkeit des Teilungsverhältnisses
Temperatur-Koeffizient
1000:1 ± 1 % bei Abschluss 10 MΩ
Weniger als 200ppm/°C
2000:1 ± 6 % bei Abschluss 1 MΩ
Genauigkeit des Teilungsverhältnisses
1000:1 ± 1 % bei Abschluss 10 MΩ
2000:1 ± 6 % bei Abschluss 1 MΩ
Temperature Coefficient
Less than 200ppm/ °C
Betriebstemperatur
0 °C bis +50 °C
Division Ratio Accuracy
1000:1 ±1% when terminated in 10 MΩ
Betriebstemperatur
Lagerungstemperatur
2000:1 ±6% when terminated in 1 MΩ
0 °C bis +50 °C
-20 °C bis +70 °C
Lagerungstemperatur
Feuchtigkeit
-20 °C bis +70 °C
Bis 80 % relative Feuchte bei +40 °C
Operating Temperature
Feuchtigkeit
0 °C to +50 °C
Bis 80 % relative Feuchte bei +40 °C
Storage Temperature:
−20 °C to +70 °C
Humidity
Up to 80% relative humidity at +40 °C
0
Atten
(dB)
-3
DC
Frequency
300 Hz
®

Advertisement

loading
Need help?

Need help?

Do you have a question about the TT-HVP 40 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Testec TT-HVP 40

  • Page 1 Unfällen führen. • Connect the divider probe common lead (alligator clip) to a good earth ground or reliable chassis TT-HVP 40 ist ein 1000:1-Teiler, der die Messkapazität eines Voltmeters auf 40 kV DC/28 kV RMS AC ground erweitert. Allgemeine Informationen •...
  • Page 2 The Testec High Voltage Probe TT HVP 40 is an accessory to be used with analog or digital multimeters This operating note must be read and understood prior to using the probe. Improper procedures or having an input resistance of 10 M Ω (± 1 %). The Testec Model TT-HVP 40 is a 1000:1 divider which Verwendung incorrect analysis of the measurement situation can result in serious shock.