Wiring Connection; Multi-Purpose Adaptor Ixw-Ma Connection Example - Aiphone IXW-MA Installation Manual

Multi-purpose adaptor
Hide thumbs Also See for IXW-MA:
Table of Contents

Advertisement

Wiring Connection

Multi-purpose adaptor IXW-MA connection example

• Insulate and secure unused low-voltage lines and the connector-attached lead wire.
Not used
Not used
2T1
2T2
1T1
1T2
Not used
Not used
1LR 1LE 1CL
2LR
2LE 2CL
S1 SE1 S2 SE2 S3 SE3 S4 SE4
Contact input 1 to 4
Same as Relay output 1 to 2.
NO1 COM1 NC1 NO2 COM2 NC2
Relay output 1 to 2
*1 Contact Input Specifications
Input method
Detection time
Contact resistance
Terminal short-circuit current
Voltage between terminals
*2 Relay Output 1 to 4 Specifications
Output method
Contact rating
Multi-purpose Adaptor
IXW-MA
Not used
3T1
3T2
Not used
3LR 3LE 3CL
NO3 COM3 NC3 NO4 COM4 NC4
Relay output 3 to 4
Programmable dry contact (N/O) or (N/C)
Level detection method
100 msec or more
Make: 700 Ω or less
Break: 3 kΩ or more
10 mA or less
5 VDC or less (between open terminals)
Form C dry contact closure (N/O or N/C)
24 VAC, 0.5 A (resistive load)
24 VDC, 0.5 A (resistive load)
Minimum overload (AC/DC): 100 mV, 0.1 mA
LAN/PoE
(IEEE802.3af)
Same as Relay output 5 to 7.
NO5 COM5 NO6 COM6NO7 COM7
NO8 COM8 NO9 COM9 NO10 COM10
Relay output 5 to 7
- 9 -
Cat-5e/6 straight
100m (330')
PE0.65mm(22AWG)-2C
PE0.65mm(22AWG)-2C
PE0.65mm(22AWG)-2C
Relay output 8 to 10
PoE switch
Contact input
1 to 4 *
1
Relay output
1 to
2 *
2
Relay output
3
5 to 7 *