DYNAPACK "S" SERIES
DYPA18AC1A036, DYPA18AC1A048, DYPA18AC1A060
DYPA24AC1A036, DYPA24AC1A048, DYPA24AC1A060
DYPA30AC1A036, DYPA30AC1A048, DYPA30AC1A060
DYPA36AC1A036, DYPA36AC1A048, DYPA36AC1A060
VERTICAL PACKAGED AIR CONDITIONER FEATURING GAS HEAT AND ELECTRIC COOLING
INSTALLATION, OPERATING AND SERVICE INSTRUCTIONS
This book contains instructions for installation and operation of your unit. Keep it in a safe place for ready reference.
WARNING!
If the information in these instructions are not followed exactly, a fire or
explosion may result causing property damage, personal injury or loss of life.
Do not store or use gasoline or other flammable vapors and
liquids in the vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your
building.
Immediately call your gas supplier from a neighbor's phone.
Follow the gas supplier's instructions.
If you cannot reach a gas supplier, call the fire department.
Installation and service must be performed by a qualified
installer, service agency or the gas supplier.
WARNING!
Improper installation, adjustment, alteration, service or maintenance can
cause property damage, personal injury or loss of life. Refer to the installation instructions
and/or owners manual provided with this appliance. Installation and service must be
performed by a qualified installer, service agency or the gas supplier.
WARNING!
Installation and servicing of air conditioning equipment can be hazardous
due to internal refrigerant pressure and live electrical components.
qualified service personnel should install or service this equipment. Installation and service
performed by unqualified persons can result in property damage, personal injury, or death.
WARNING!
For SAFE operation this must be installed using only the approved exterior
grille and wall sleeve accessories. Failure to comply with this may result in property
damage, personal injury, or death.
CAUTION:
The installation of this appliance must conform to the requirements
of the National Fire Protection Association; the National Electrical Code, ANSI/
NFPA No. 70 (latest edition) in the United States; the Canadian Electrical Code
part 1, CSA 22.1 (latest edition) in Canada; and any state or provincial laws
or local ordinances. Local authorities having jurisdiction should be consulted
before installation is made. Such applicable regulations or requirements take
precedence over the general instructions in this manual.
INSPECTING FOR FREIGHT DAMAGES
Your unit was carefully packed in a container which complies with the National
Safe Transit Test. This means that the packaged product, with normal handling,
will withstand the load conditions encountered in normal transit and in handling.
Your unit should be inspected immediately after unpacking to determine if any
damage is present due to shipping or handling. If any damage is discovered,
do not install the unit. Notify the transportation company immediately and file a
damage claim.
The manufacturer can bear no responsibility for damages which occur in transit or
for improper operation of the unit as a result of shipping damages.
Part Number 205094
10/02/2017 Rev. 6
MODELS
DYPA12AC1A036, DYPA12AC1A048
Installer: Leave this manual with the appliance
Consumer: Retain this manual for future reference.
Should you require further information, contact your dealer.
Only trained and
For future reference, you should record the following information from the units.
MODEL NUMBER _________________________________________________
SERIAL NUMBER _________________________________________________
STOCK NUMBER _________________________________________________
DATE OF PURCHASE _____________________________________________

UNIT SPECIFICATIONS

Do not operate this unit during construction as this may violate your
warranty.
HEATING
DYPA
DYPA
12AC1A036
18AC1A036
BTU INPUT
35,500
35,500
VOLTS
208-230
208-230
AMPS
5.2
5.2
GAS
CONNECTION
COOLING
DYPA
DYPA
12AC1A036
18AC1A036
COOLING
12,000
17,500
CAPACITY
VOLTS
208-230
208-230
WATTS
1175
1665
*MCA
13.3
14.9
REFRIGERANT
REFRIGERANT
CHARGE
*MCA = Minimum Circuit Ampacity
AIRXCEL, INC.
SUBURBAN APPLIED PRODUCTS
156 Seedling Drive
Cordele, GA 31015
(229) 273-3636
www.SuburbanManufacturing.com
MODEL
DYPA
DYPA
DYPA
24AC1A048
30AC1A060
36AC1A060
47,500
59,000
59,000
208-230
208-230
208-230
5.2
5.2
5.2
/
1
Inch Pipe at Unit
2
MODEL
DYPA
DYPA
DYPA
24AC1A048
30AC1A060
36AC1A060
25,200
30,200
34,800
208-230
208-230
208-230
2380
2820
3480
17.8
21.6
25.2
R410A
SEE INFORMATION
STICKER ON UNIT

Advertisement

Table of Contents
loading

Summary of Contents for Suburban DYNAPACK S Series

  • Page 1: Unit Specifications

    AIRXCEL, INC. SUBURBAN APPLIED PRODUCTS 156 Seedling Drive Cordele, GA 31015 (229) 273-3636 www.SuburbanManufacturing.com DYNAPACK "S" SERIES MODELS DYPA12AC1A036, DYPA12AC1A048 DYPA18AC1A036, DYPA18AC1A048, DYPA18AC1A060 DYPA24AC1A036, DYPA24AC1A048, DYPA24AC1A060 DYPA30AC1A036, DYPA30AC1A048, DYPA30AC1A060 DYPA36AC1A036, DYPA36AC1A048, DYPA36AC1A060 VERTICAL PACKAGED AIR CONDITIONER FEATURING GAS HEAT AND ELECTRIC COOLING...
  • Page 2: Installation

    Installation of this appliance must be made in accordance with the written instructions provided in this manual. No agent, representative or employee of Suburban or other person has the authority to change, modify or waive any provision of the instructions CAUTION: The sleeve will support the back of the unit.
  • Page 3: Air Filter

    INSTALLING AND SECURING UNIT DUCT WORK The duct work for the dwelling should be designed for the lowest TO WALL SLEEVE possible static pressure to reduce energy usage and noise. Table 2 lists Before installing and securing the unit to the wall sleeve, make sure the approximate cfm delivery of the units on each of the indoor blower that the proper grille kit is installed.
  • Page 4: Gas Piping

    ½ psig or 14” water column for this test or the gas valve may be damaged. CAUTION: Suburban does not recommend the use of flex tubing to OUTLET PRESSURE POST. make the gas connections to the unit unless the flex tubing is a high TEST HOSE GOES OVER OUTSIDE OF POST.
  • Page 5: Requirements For Installation

    The thermostat will call for heat and the combustion blower will REQUIREMENTS FOR INSTALLATION begin to operate. Commonwealth of Massachusetts The combustion blower will operate for 15 to 20 seconds before the ignition controls begins sparking, then the gas valve will open For all side wall horizontally vented gas fueled equipment installed and the burners will light.
  • Page 6: System Performance

    OPERATION IN EXTREME COLD OR SNOWY AREAS If the air temperature drop is greater than 22 degrees then switch the cooling In those areas where the ambient temperature is consistently below speed to the next higher speed. If the air temperature drop is less than 18 degrees then switch the cooling speed to the next lower blower speed.
  • Page 7 Nominal LENGTH OF PIPE (Feet) Internal Iron Pipe Diameter, Size, Inches Inches .364 .493 .622 .824 1.049 1 - 1/4 1.380 1,050 1 - 1/2 1.610 1,600 1,100 2.067 3,050 2,100 1,650 1,450 1,270 1,150 1,050 2 - 1/2 2.469 4,800 3,300 2,700...
  • Page 8: Wall Sleeve

    208/230V 60 Hz 1Ø POWER SUPPLY COMP WALL SLEEVE INDUCER NOTE 2 NOTE 1 230V TRANSFORMER VALVE SPARK IGNITER FLAME SWITCH BLOWER LIMIT HIGH LIMIT SWITCH FLAME 24 VAC UNUSED GROUND ACB HEAT ACB COOL REQUIRED WALL OPENING ROLLOUT SWITCH PRESSURE CMB BLOWER SWITCH...
  • Page 9 Figure 8...
  • Page 10 Please consult the Suburban Applied Products website at www.SuburbanManufacturing.com for the latest product literature. Detailed dimensional data is available upon request. A complete warranty statement can be found in each product’s Installation/Operation Manual, on our website. As part of the Suburban continuous improvement program, specifications are subject to change without notice. Manufactured by: P.O.
  • Page 11 APPENDIX A The Dynapack condensate drain system is designed to be installed in a conditioned space. To prevent freezing of the drain condensate in the P-Trap, the installation location should not be exposed to freezing conditions. In installations where the drain system is exposed to freezing conditions, we offer an optional heated P-Trap which is available for purchase.