Suburban DYNALINE DL3-0712 Owner’s Manual Installation, Operating And Service Instructions

Packaged terminal air conditioner
Hide thumbs Also See for DYNALINE DL3-0712:

Advertisement

PACKAGED TERMINAL AIR CONDITIONER
MODELS: DL3-0712 • DL3-0912 • DL3-1220 • DL3-1622
INSTALLATION, OPERATING AND SERVICE INSTRUCTIONS
This book contains instructions for installation and operation of your unit. Keep it in a safe place for ready reference.
WARNING!
If the information in these instructions are
not followed exactly, a fire or explosion may result causing
property damage, personal injury or loss of life.
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use
any phone in your building.
• Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
• If you cannot reach a gas supplier, call the fire
department.
Installation and service must be performed by
a qualified installer, service agency or the gas
supplier.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
WARNING!
Improper installation, adjustment, alteration,
service or maintenance can cause property damage, personal
injury or loss of life. Refer to the installation instructions and/
or owners manual provided with this appliance. Installation
and service must be performed by a qualified installer, service
agency or the gas supplier.
FOREWORD
You have just purchased a Suburban Packaged Terminal Air Conditioner. Models
0712, 0912, 1220 AND 1622 are certified by the Canadian Standard Association
under Z21.86-2008/CSA 2.32-2008 UL484.
To simplify the proper installation and to assure that the unit will operate in
conformity with generally accepted safety regulations, it requires that you read
carefully and fully understand the step-by-step instructions outlined in this manual.
CAUTION: Due to the differences in vinyl siding, this appliance should not
be installed on vinyl siding without first consulting with the manufacturer
of the siding or cutting the siding away from the area around the appliance
vent.
NOTE: Do not deviate from the instructions as outlined in this manual. Failure
to follow the installation, operating and maintenance instructions will void the
responsibility of Suburban Manufacturing Company.
Part Number 81758
10-31-2017
DYNALINE
OWNER'S MANUAL
Should you require further information, contact your dealer.
Your unit was carefully packed in a container which complies with the National
Safe Transit Test. This means that the packaged product, with normal handling,
will withstand the load conditions encountered in normal transit and in handling.
Your unit should be inspected immediately after unpacking to determine if any
damage is present due to shipping or handling. If any damage is discovered, do
not install the unit. Notify the transportation company immediately and file a
damage claim.
The manufacturer can bear no responsibility for damages which occur in transit or
for improper operation of the unit as a result of shipping damages.
For future reference, you should record the following information from the units.
MODEL NUMBER _______________________________________________
SERIAL NUMBER ______________________________________________
STOCK NUMBER _______________________________________________
DATE OF PURCHASE ___________________________________________
Do not operate the unit during construction period; this
may be a breach of the warranty conditions.
BTU INPUT
VOLTS
AMPS
GAS
CONNECTION
COOLING
CAPACITY
VOLTS
WATTS
REFRIGERANT
CHARGE
REFRIGERANT
1
SUBURBAN APPLIED PRODUCTS
www.SuburbanHVACproducts.com
INSPECTING FOR FREIGHT DAMAGES

UNIT SPECIFICATIONS

HEATING
DL3-0712
DL3-0912
12,000
12,000
208/230
208/230
2.0
2.0
3/8" IPS
3/8" IPS
COOLING
DL3-0712
DL3-0912
7600/7800
9300/9500
208/230
208/230
675/705
830/855
SEE INFORMATION STICKER ON UNIT
Suburban DynaLine Owner's Manual 10/2017 Rev.1
AIRXCEL, INC.
156 Seedling Drive
Cordele, GA 31015
(229) 273-3636
MODEL
DL3-1220
DL3-1622
18,000
20,000
208/230
208/230
2.0
2.0
3/8" IPS
3/8" IPS
MODEL
DL3-1220
DL3-1622
11500/11700
15000
208/230
208/230
1075/1125
1520/1580
R410A

Advertisement

Table of Contents
loading

Summary of Contents for Suburban DYNALINE DL3-0712

  • Page 1: Unit Specifications

    3/8” IPS 3/8” IPS 3/8” IPS 3/8” IPS CONNECTION You have just purchased a Suburban Packaged Terminal Air Conditioner. Models 0712, 0912, 1220 AND 1622 are certified by the Canadian Standard Association COOLING under Z21.86-2008/CSA 2.32-2008 UL484. MODEL To simplify the proper installation and to assure that the unit will operate in...
  • Page 2: Installation

    NOTE: If mounted on top of floor, the gas connection MINIMUM OPERATIONAL CLEARANCES should be made from rear of unit. For the best finished results, Suburban suggests the wall sleeve be mounted a minimum of 3-1/2” off of the finished The following minimum outside clearance from rear grille must be maintained: floor, as illustrated in Figure 3.
  • Page 3: Operating Pressure

    3. Depress “Fan” key pad until desired speed lamp is illuminated. In order to maintain a check on gas supply pressure to the unit, Suburban advises the installer to provide a 1/8” NPT plug tap for test gauge connection immediately 4.
  • Page 4 The glo-bar remains on another 3 seconds CAUTION: Airborne dust particles can enter the detector. Suburban recommends after the valve opens and then goes off. When the valve opens, it will remain the installation of Dynaline units with System Sensor carbon monoxide detectors open for 6 seconds.
  • Page 5: Preventive Maintenance

    If cycling happens too often or for an prior to operating the unit. extended period, the circulating air system should be thoroughly cleaned. (See “Maintenance and Cleaning.”) Suburban DynaLine Owner's Manual 10/2017 Rev.1...
  • Page 6: Filter Removal

    1,130 1,050 3.068 8,500 5,900 4,700 4,100 3,600 3,250 3,000 2,800 2,600 2,500 2,200 2,000 1,850 1,700 4.025 17,500 12,000 9,700 8,300 7,400 6,800 6,200 5,800 5,400 5,100 4,500 4,100 3,800 3,500 TABLE 2 Suburban DynaLine Owner's Manual 10/2017 Rev.1...
  • Page 7 CABINET FRONT REAR GRILL VENT CAP ASSEMBLY UNIT OVERALL DIMENSIONS Figure 1 HEADER (STEEL LINTEL IN BRICK CONSTRUCTION) 1" MIN. 1" MIN. SURFACE OF FINISHED FLOOR WALL SLEEVE FRAMING DIMENSIONS REAR GAS HOOK-UP Figure 2 Suburban DynaLine Owner's Manual 10/2017 Rev.1...
  • Page 8: Wall Installation

    SLEEVE IS FLUSH WITH 1" FINISHED INTERIOR WALL. SLOPE DOWN TO THE OUTSIDE 5" SURFACE OF FINISHED MIN. (PROJECTION BEYOND EXTERIOR WALL) FLOOR OR TOP OF CARPET WALL INSTALLATION REAR GAS HOOKUP Figure 5 Suburban DynaLine Owner's Manual 10/2017 Rev.1...
  • Page 9 (4) LEVEL UNIT BY ADJUSTING SCREW IN LEG. CABINET FRONT WALL SLEEVE 1" SLOPE DOWN TO THE OUTSIDE LEVELING LEGS SURFACE OF FINISHED FLOOR 5" MAX./3 1/2" MIN. OR TOP OF CARPET SIDE VIEW FRONT VIEW LEVELING LEGS INSTALLATION Figure 8 Suburban DynaLine Owner's Manual 10/2017 Rev.1...
  • Page 10 FOR REMOTE THERMOSTAT. THE 5/8" STRAIN RELIEF BUSHING PROVIDED IN THE PACK-OUT BAG SUPPLIED WITH THE UNIT MUST BE USED TO SECURE THE THERMOSTAT WIRING FOR REMOTE THERMOSTAT. Figure 12 CONTROL ROD (FRESH AIR VENT) Figure 13 Suburban DynaLine Owner's Manual 10/2017 Rev.1...
  • Page 11 W/BK THE APPLIANCE MUST BE REPLACED, IT MUST BE REPLACED WITH TYPE 105ĀC WIRE OR TYPE 150ĀC 208/230 V.A.C. WIRING DIAGRAM WIRE WHERE SPECIFIED OR ITS EQUIVALENT. 81857 WITHOUT CARBON MONOXIDE DETECTOR Figure 15a Suburban DynaLine Owner's Manual 10/2017 Rev.1...
  • Page 12 RETIRER LES QUATRE (4) VIS DES CONDENSER COVER SUPPORTS ET RETIRER LES SUPPORTS RETIRER LES DEUX (2) VIS ET RETIRER LE COUVERCLE DU CONDENSEUR BURNER CHAMBER YELLOW OUTER FLAME INCORRECT FLAME ERRATIC PATTERN Figure 17 Suburban DynaLine Owner's Manual 10/2017 Rev.1...
  • Page 13 Suburban DynaLine Owner's Manual 10/2017 Rev.1...
  • Page 14: Optional Accessories

    These grilles will also work, as designed, for those models with rear gas hook- up. IMPORTANT: Installation of the rear grille must be made prior to installing the chassis as it secures from inside the wall sleeve. WALL SLEEVE SCREW (5) REQUIRED Figure 19 Suburban DynaLine Owner's Manual 10/2017 Rev.1...
  • Page 15 BOTTOM OF SLEEVE TO TOP OF AIR DISCHARGE ADAPTOR Figure 20 Figure 21 4 PIN MALE HOUSING (ONLY FOR UNITS WITH OPTIONAL CARBON MONOXIDE DETECTOR) 4 PIN FEMALE HOUSING RESET BUTTON TEST/HUSH BUTTON OPTIONAL CARBON MONOXIDE DETECTOR Figure 22 Suburban DynaLine Owner's Manual 10/2017 Rev.1...
  • Page 16 NFPA 54 as adopted by the Board; and Product Approved side wall horizontally vented gas fueled equipment installed in a room or structure separate from the dwelling, building or structure used in whole or in part for residential purposes. Suburban DynaLine Owner's Manual 10/2017 Rev.1...
  • Page 17 THE PRODUCT IS REINSTALLED ELSEWHERE. Suburban reserves the right to examine the alleged defect in the unit or component parts, and it is the owner's obligation to return the unit and/ or component parts to Suburban or its representative. When returning a unit, it must include all component parts and the serial number plate.

This manual is also suitable for:

Dynaline dl3-0912Dynaline dl3-1220Dynaline dl3-1622