Terra tdx410C Manual page 5

Dvb-s/s2 & dvb-t/t2/c to dvb-t transmodulators
Table of Contents

Advertisement

Device information table
This shows the data of module:
"Device model": model of the module.
"Serial number": serial number of the module.
"Software version": module software version number.
"Hardware version": module hardware version number.
"IP": IP address of the control interface.
"System time": current time, synchronized from the TDT table of the input stream. Local time offset can be selected in
the "IP settings" tab, see section 7.4.
"Up time": time passed from last power-up or restart of the module.
In the "Common status" table the following parameters are displayed at real time: input bit rate in kbps, output bit rate in
kbps, processor load in percents, internal temperature in degrees of Celsius, power voltage in Volts.
In the "Diagnostic information" table all module errors and comments how to eliminate these errors are displayed.
7.3 RF input/output settings
This screen consists of six tables: "RF input", "RF output", "List of services", "Input status", "RF output status", "Description
of other streams in the network". The "RF input" table is used to configure parameters corresponding to the input satellite
transponder (tdx410C module), terrestrial or cable transponder (ttx410C module). In the "List of services" table the list of
services, available in the input transponder is displayed. In the "Input status" table you can see real time status of the input
section. In the "RF output status" table you can see real time status of the output section.
The "RF input" table is different according to the input signal of module.
7.3.1. RF input table
The „RF input" table (Figure 9) for tdx410C module consists of the following parameters:
"LNB LO frequency" - the LNB local oscillator lower frequency in megahertz. Use 9750 MHz for the universal converter.
"LNB HI frequency" - the LNB local oscillator upper frequency in megahertz. Use 10600 MHz for the universal converter.
"LNB voltage" – power supply of the converter – can be set to "Off", "Auto", "13V", "18V", "13V/22kHz", "18V/22kHz". If
"Auto" is selected, power supply voltage of the converter is chosen according to set the polarization – 18V Horizontal, 13V
Vertical; if the "Frequency" of the satellite exceeds the value F=(950+LNB Hi+2150+LNB Lo)/2, the 22 kHz signal is switched
ON and "LNB Hi freq." is selected.
For example: LNB Hi=10,600, LNB Lo=9750, then F=(950+10,600+2150+9750)/2=11,725 MHz. When power supply of
the converter is set to value different from "Auto." to "LNB HI frequency", "Satellite" and "Polarization" rows are disabled
and the "LNB LO frequency" value is used for IF frequency calculation.
"Satellite" – DISEQC command is used to select the satellite when the switch that supports DISEQC protocol is present.
Possible commands: "None", "SAT A", "SAT B", "SAT C", "SAT D".
"Polarization" - the polarization of converter. Can be "Horizontal" or "Vertical".
"Frequency" – the frequency of the satellite transponder in megahertz.
"Symbol rate" – the symbol rate of the satellite transponder in kilo symbols per second.
Figure 8. Diagnostic information table with errors
Figure 9. The "RF input" table of the tdx410C module
5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ttx410c

Table of Contents