7. Operating
7.1 Initial configuration
All modules leave the factory with this control: Ethernet interface IP address: 192.168.1.10. In order to avoid conflicts
with other IP addresses, it is necessary to perform an initial configuration in local mode. Subsequently, it will be possible to
access the modules via the local area network (LAN), either to re-programme it or to check its operating status.
The modules leave the factory with the following Control Ethernet interface TCP/IP configuration:
IP address of the module: 192.168.1.10
Subnet mask: 255.255.255.0
Default Gateway: 192.168.1.1
Figure 6. Login prompt
Access to the site is protected by user name and password. The default user name and password is admin. Enter the
user name and password and click on "Login" button.
Note: the default password - admin - can (and must) be changed as explained in the section 7.7.5.
During initial configuration you need to change the default control interface TCP/IP configuration as explained in the
section 7.4.
Control interface IP address reset to default procedure: press the "RESET" [7] button for more than 3 seconds and release
it. After this operation the control interface IP address will be set to 192.168.1.10, user name and password set to admin.
7.2 General configuration
Initial Web interface screen
The first screen that appears when the module accessed contains the "Main" window, which gives general information
on the device.
[1]
In the top of each configuration screen you will see a main menu tabs [1].
Using it, you can switch between the different configuration menus. The tab highlighted in yellow shows which menu is
active at a given moment. The "System menu" tab contains several submenu items.
Also common elements for all screens are module title [2] and login information strings [3]. The module title can be changed
after pressing the "Change" button in the "Device information" table. Pressing on the "Logout" string you can logout from
module control.
To access each module, use a personal computer (PC) equipped with an Ethernet card and
RJ-45 cable (CAT-5E or CAT-6). The IP address of the PC/MAC must be configured within the
following range: 192.168.1.2 - 192.168.1.254 (do not use 192.168.1.10, since this is the IP
address of the module to be configured). To start the configuration of the module, open your
web browser and type in the following direction: http://192.168.1.10. The login prompt will
appear on the screen (see Figure 6.).