Pressure Relief Procedure - Graco FinishPro HVLP 7.0 Operation - Repair - Parts

Hide thumbs Also See for FinishPro HVLP 7.0:
Table of Contents

Advertisement

Pressure Relief Procedure

Pressure Relief Procedure
Follow
Procedure whenever you see this
symbol.
The spray gun cup is pressurized. To
reduce the risk of splashing from
pressurized fluid, always follow the
Pressure Relief Procedure before
removing cup.
1.
Turn the ON/OFF switch to OFF
position.
Standard Models:
ti30625a
ProContractor and ProComp Models:
2.
Unplug power cord to disconnect power.
3.
Disconnect spray gun from air hose.
10
the
Pressure
Relief
If using a FlexLiner System:
4.
Disconnect tubing from gun to relieve
pressure in the cup.
If using a ProComp remote cup:
5.
Turn compressor ON/OFF switch to OFF
position.
ti30756a
ti30892a
6.
Disconnect air hose from remote cup.
Turn out pressure regulator one turn.
Wait until pressure is completely
relieved before removing cover.
ti30756a
ti30757a
ti30627a
ti30893a
3A4967C

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Finishpro hvlp 9.0Finishpro hvlp 9.5

Table of Contents