Separate receivers
Common receiver
CAUTION
© Copyright 2014 ABB. All rights reserved.
Operation Manual / TPL65-A32 / -A33 / -A36 + TPL69-A32 / -A33
Taking out of operation at short notice
Fit cover plate
Further measures and information for operation with a turbocharger with
cover plate on 4-stroke engines
4-stroke engine with one turbocharger
No further measures are necessary. The engine can be operated as a
naturally-aspirated engine according to the engine builder's instructions.
4-stroke engine with several turbochargers
No further measures are necessary on engines with separate air and
exhaust gas receivers. The engine can be operated as a naturally-
aspirated engine according to the engine builder's instructions.
The air line must be closed off at the engine end because the undamaged
turbochargers build up a receiver pressure.
The engine can be operated according to the engine builder's
instructions. Attention must always be paid to the speed of the
undamaged turbocharger. The speed limit n
plate must not be exceeded.