Notices RIGOL products are covered by P.R.C. and foreign patents, issued and pending. RIGOL reserves the right to modify or change parts of or all the specifications and pricing policies at the company’s sole decision. Information in this publication replaces all previously released materials.
Options and accessories provided by DSA700 series spectrum analyzer are as shown in the table below. If needed, please contact RIGOL or the local distributors. This manual only introduces the functions of some options. For the option with remark in the table below, refer to the dedicated manual.
Page 6
[2] For more details, refer to the corresponding manual (included in the option package in hard copy form, or download the manual from www.rigol.com). [3] For more details of this accessory, refer to the help document of S1210 EMI Pre-compliance Software (you can call the manual by clicking Help in the menu bar of the software, or download the manual from www.rigol.com).
RIGOL Standard Accessories The following are the standard accessories. Power Cord Quick Guide Note: Images in this section are indicative only. The actual products you receive may differ. DSA700 Options and Accessories...
RIGOL EMI Filter and Quasi-Peak Detector EMI-DSA800 option provides Quasi-Peak detector and EMI filter (200 Hz, 9 kHz, 120 kHz, -6 dB bandwidth). Quasi-Peak detection is a weighted form of peak detection. For each data point, the detector detects the peaks within the specified time interval,...
RIGOL Advanced Measurement Kit AMK-DSA800 option provides various measurement functions, including T-Power, ACP (Adjacent Channel Power), Chan Pwr (Channel Power), OBW (Occupied Bandwidth), EBW (Emission Bandwidth), C/N Ratio, Harmo Dist (Harmonic Distortion) and TOI (Third Order Intermodulation). For advanced measurement functions, the measurement mode can be single or continuous and you can control the measurement including Restart, Pause and Resume.
Page 10
RIGOL 2. ACP Measure the powers of the main channel and adjacent channels as well as the power difference between the main channel and each of the adjacent channels. When this function is enabled, the span and resolution bandwidth of the analyzer are adjusted to smaller values automatically.
Page 11
RIGOL Integration Bandwidth Channel Power Span 4. OBW Integrate the power within the whole span and calculate the bandwidth occupied by this power according to the specified power ratio. The OBW function also indicates the difference between the center frequency of the channel under measurement and the center frequency of the analyzer.
Page 12
RIGOL 5. EBW Measure the bandwidth between two points on the signal which are X dB below the highest point within the span. 6. C/N Ratio Measure the powers of the carrier and noise with the specified bandwidths as well as their power ratio.
Page 13
RIGOL 7. Harmo Dist Measure the power of each order of harmonic and THD (total harmonic distortion) of the carrier. The highest order of harmonic available is 10 and the fundamental wave amplitude must be greater than -50 dBm, or else the measurement will be invalid.
Page 14
RIGOL 8. TOI Measure the parameters of the TOI production of two signals with the same amplitude and similar frequency. Those parameters include the frequencies and amplitudes of the Base Lower, Base Upper, 3rd Order Lower and 3rd Order Upper signal, as well as the Intercepts of both the Base Lower and Base Upper.
RIGOL USB-GPIB Interface Converter Through the RIGOL USB-GPIB interface converter, the spectrum analyzer can be connected to the GPIB bus controller of the PC, namely to expand a GPIB interface through which the spectrum analyzer can finish various tasks using the GPIB instructions more easily for the spectrum analyzer.