Gs, gl & gt series fully steam jacketed gas kettles (12 pages)
Summary of Contents for Vulcan-Hart VDLT Series
Page 1
TILTING 2/3 JACKETED KETTLES SERIES: VDLT&VDPT Vulcan service agencies are located throughout the United States. For location and phone number of one near you, call your local Vulcan dealer. VULCAN-HART CORPORATION, P.O. BOX 696, LOUISVILLE, KY 40201-0696, TEL. (502) 778-2791 FORM 30015(2-90)
Page 2
IMPORTANT OPERATING, INSTALLING AND SERVICE PERSONNEL The operating information on this equipment has been prepared for use by qualified and/or authorized operating personnel. All installation and service on this equipment is to be performed by qualified, certified, licensed and/ or authorized installation or service personnel, with the exception of any part marked with a D in front of the part number.
INDEX Your Vulcan Steam Jacketed Tilting Kettle is produced this entire manual and carefully follow all of the with quality workmanship and material. Proper installa- instructions provided. Save this manual for future tion, usage and maintenance will result in many years reference.
DESCRIPTION The Vulcan direct steam jacketed kettles in this manual are tilting, and are to be permanently floor mounted are pressure vessels of double-wall stainless steel con- either on legs with adjustable flanged feet or on a struction forming a sealed jacket reservoir around the pedestal.
INSTALLATION Connect steam line ( /4" pipe size) to the kettle, WARNING: PLUMBING CONNECTIONS MUST making sure there is a steam control valve COMPLY WITH APPLICABLE strainer (not supplied) fairly convenient to the HEALTH, SAFETY AND PLUMBING kettle. CODES. Connect the kettle condensate return line to a Select a location to provide drainage directly below drain or to a boiler return line.
OPERATION ciency the air should be exhausted from the jacket by The relief valve is installed towards the rear of the opening the relief valve until the air has been kettle jacket. If the pressure in the jacket reaches the completely replaced by pressurized steam.
CLEANING The kettle interior and exterior should be thoroughly On draw off models, by hand, turn the large hex washed after each use when a different food is to be nut on the (optional) draw off valve cooked next or when cooking is completed for the day. counterclockwise until it is completely disengaged Before cleaning check that the kettle has cooled from the threads.
SERVICE DRAW OFF VALVE LEAKS (DRAW OFF MAINTENANCE VALVE IS OPTIONAL) No general maintenance is required other than If a leak occurs through the valve stem, replace the "0" following the cleaning procedures. ring. If the leak is due to faulty sealing between the stem disc and valve seat, this problem can usually be corrected by cleaning off the dried on food residue with an extremely fine emery cloth.