Electrical Requirements; Temperature; Communicators; Tags - TagMaster S1566 Installation Manual

Hd reader
Table of Contents

Advertisement

TagMaster AB
HW Installation Guide
8

ELECTRICAL REQUIREMENTS

The following characteristics apply under following conditions:
8.1

Temperature

8.1.1

Communicators

In most applications, normal convection cooling is enough. In applications where heat is
generated close to the Reader, forced cooling or heat shields may be necessary.
The S1566 has the following characteristics: Environmental temperature: -25 to +60° C.
8.1.2

Tags

TagMaster Tags are available for operation in various ambient temperatures ranging from -40°C
up to 85°C, refer to the data sheets. The specified reading range is valid for normal ambient
temperature conditions. If reading range is critical and the intended operating temperature
deviates from normal ambient temperature TagMaster AB should be consulted.
8.2

Supply Voltage

The Reader is supplied with external DC to the connector (pin P=12 V and pin R=0 V (return)).
Item
Supply voltage
Ripple/noise
Consumption
Notes:
1
The input DC power must be within these limits.
2
The maximum ripple and noise on the supply power to the Communicator.
8.3

Radio Interface

Item
Frequency range
Frequency deviation
Output power EIRP high
Output power EIRP low
Lobe width horizontal
Lobe width vertical
Harmonics EIRP
AM modulation ratio
ELECTRICAL REQUIREMENTS
Symbol
Min
Vspl
10
Nspl
Ispl
Symbol
fc
fdev
Pohh
Polh
Lh
Lv
Aam
Typical
Max Unit
12
14
50
250
500
Min
Type Max Unit
2435
8
-2
40
45
40
45
15
Manual issue 01
Notes
V
1
mV
2
mA
2465 MHz
± 100 kHz
10
dBm
dBm
50
deg
50
deg
15
nW/4 kHz
dB
Notes
1
2
3,4
3;4
5
5
6
7
13