Appropriate Use - elobau 471 M41 H31 Translation Of The Original Operating Instructions

Table of Contents

Advertisement

Available languages

Available languages

GB
LED
4
5
6
7
8
9
10
Switches
Switch
1
2
3
4
5
6
7
8
2

Appropriate use

The control unit is intended for use exclusively to protect against hazards.
2.1 Safety/Dangers
General
-
Ensure that the control unit is only installed and put into operation by special-
ly-trained authorised personnel.
-
Ensure that the appropriate corresponding fuses (see Technical data) are
used. Never bridge or repair fuses.
-
Only operate the control unit when it's in an undamaged condition.
22
Meaning when LED is lit
Sensor 2, both contacts actuated
Sensor 3, both contacts actuated
Sensor 4, both contacts actuated / EMERGENCY STOP not
actuated
Safety output 1 is switched through
Safety output 2 is switched through
Safety output 3 is switched through
Safety output 4 is switched through
Function
Delay 8 s
Delay 4 s
Delay 2 s
Delay 1 s
Sensor 4 B/M
2-hand control
Sensor 4: 3 or 4-wire
No function
900565 / 04.04.2016