elobau 471 M41 H31 Translation Of The Original Operating Instructions page 21

Table of Contents

Advertisement

Available languages

Available languages

GB
1.2 Type denomination/Variants
The following example and table are given to explain the type denomination of
the control units.
Example:
471 M41 H31
4ab cde fgh
Placeholder Characteristic
4ab
Housing type and
housing width
c
Version
d
Inputs
e
Operating voltage
f
Other
g
Output
h
Switching voltage
1.3 Electrical and mechanical data
The control unit in a deenergized state is depicted on the circuit diagram of the
fold-out page.
Operating voltage
Power consumption
Floating
Switching voltage safety outputs
Switching current safety outputs
Switching power safety outputs
Switching voltage control outputs
Switching current control outputs
Switching power control outputs
Max. number of **switching operations
for 0.5 A switching current
(ohmic load, 250 V AC)
20
Meaning
471
Housing width 45 mm
M
Microcontroller version
4
4 inputs
1
24 V
H
Category 4 according to DIN
EN ISO 13849-1
3
Relay output
1
30 V
24 V DC +/- 15 %
850 mA
Safety outputs
30 V AC/DC
3 A
90 VA or 90 W
24 V DC
100 mA
2.4 W
6
3 x 10
900565 / 04.04.2016