Temperature Increase Above Ambient Water Temperature - STIEBEL ELTRON DHC 3-1 Operation And Installation

Tankless electric water heater
Table of Contents

Advertisement

Available languages

Available languages

INSTALLATION
TECHNICAL DATA
DHC 6-2, DHC 8-2, DHC 10-2
A
2/GRD ~ 208 / 240 V
DHC 9-3
B
1/N/GRD ~ 277 V
DHC 3-1
B
1/N/GRD ~ 120 V
V
A
B
WWW.STIEBEL-ELTRON-USA.COM
L L
N L
11.3 Temperature increase above ambient water
temperature
[ °f ]
Typ
kW
gPM (gallon per minute)
0.32 0.42 0.48 0.5
DHC 3-1
3.0
65
49
43
DHC 3-2
2.5
54
40
35
3.3
71
53
47
DHC 4-2
2.9
47
41
3.8
61
54
DHC 4-3
4.5
73
64
DHC 5-2
3.6
58
51
4.8
77
68
DHC 6-2
4.5
64
6.0
85
DHC 8-2
5.4
7.2
DHC 9-3
9.0
-
-
-
DHC 10-2
7.2
-
9.6
-
Min. water flow to activate unit
[ °C ]
Typ / Type
kW
l/min
1.2
1.6
1.8
DHC 3-1
3.0
36
27
24
DHC 3-2
2.5
30
22
20
3.3
39
30
26
DHC 4-2
2.9
26
23
3.8
34
30
DHC 4-3
4.5
40
36
DHC 5-2
3.6
32
29
4.8
43
38
DHC 6-2
4.5
36
6.0
48
DHC 8-2
5.4
7.2
DHC 9-3
9.0
-
-
-
DHC 10-2
7.2
9.6
Min. water flow to activate unit
0.69 0.75 0.79 1.0
1.5
41
30
27
26
20
14
34
25
23
21
17
11
45
33
30
28
22
15
40
29
26
25
20
13
52
38
35
33
26
17
61
45
41
39
31
20
49
36
33
31
25
16
65
48
44
41
33
22
61
45
41
39
31
20
82
60
55
52
41
27
54
49
46
37
25
71
65
62
49
33
-
-
-
77
58
41
62
49
33
82
65
44
2.0
2.6
3.0
4.0
5.0
7.5
22
17
14
11
9
6
18
14
12
9
7
5
24
18
16
12
9
6
21
16
14
10
8
6
27
21
18
14
11
7
32
25
22
16
13
9
26
20
17
13
10
7
34
26
23
17
14
9
32
25
22
16
13
9
43
33
29
22
17
11
30
26
19
15
10
40
34
26
21
14
-
-
43
32
26
17
34
26
21
14
46
34
28
18
DHC |
2.0
10
9
11
10
13
15
12
16
15
20
18
25
31
25
33
9

Hide quick links:

Advertisement

Table of Contents
loading