INSTALLATION
Installation
f Mark out the holes for drilling with the installation template.
f
f Drill the holes and insert suitable rawl plugs.
f
Note:
The drill holes can be used when replacing a DHC appli-
ance. Use the supplied large washer for the upper hole.
f Tighten the two fixing screws to the correct insertion depth.
f
DHC 3, DHC 4,
DHC 6, DHC 8
f Prepare the power cable.
f
DHC 3, DHC 4,
DHC 6, DHC 8
f Insert both connectors. Observe the insertion depth.
f
DHC 3,
DHC 4,
DHC 6,
DHC 8
f Cut an opening in the cable grommet suitable for the select-
f
ed power cable.
f Install the cable grommet in the back panel.
f
f Route the power cable through the appliance back panel.
f
WWW.stiebel-eltron.com
115
50
46 - 50
DHC 3, DHC 4,
DHC 6, DHC 8
f Mount the appliance back panel over the screws and slide the
f
appliance back panel downwards.
f DHC 3, DHC 4, DHC 6, DHC 8: Secure the connection pipes
f
with the supplied flat gaskets onto the connectors.
f Align the appliance and tighten the fixing screws securely.
f
Connecting the power supply
Warning Risk of electrocution
Carry out all electrical connection and installation work
in accordance with relevant regulations.
Warning Risk of electrocution
f Ensure that the appliance is earthed.
f
Connection to the power supply is only permissible in
the form of a permanent connection in conjunction with
the removable cable grommet. The appliance must be
able to be separated from the power supply by an isola-
tor that disconnects all poles with at least 3 mm contact
separation.
Material damage
!
Observe the type plate. The specified voltage must match
the mains voltage.
f Connect the power cable to the mains terminal (see chapter
f
"Specification / Wiring diagram").
10.1 Alternative installation options only for
DHC 4, DHC 6, DHC 8
- Power supply from above on finished walls
- Power supply from below on finished walls
- Water installation for finished walls
f Cut or break out the required entries in the appliance back
f
panel cleanly (for positions, see chapter "Specification / Di-
mensions and connections"). If necessary, use a file.
DHC 6 U
DHC 3,
DHC |
21