ACRYLIC FLOW METERS
0 - 3 0 , 0 - 7 0 & 0 - 1 2 0 L P M
A S S E M B L Y
I N S T R U C T I O N S
&
I N S T R U C T I O N S F O R U S E
R 2 1 9 P 8 6 ( 0 - 1 2 0 L P M )
R 2 1 9 P 8 7 ( 0 - 7 0 L P M )
R 2 1 9 P 8 8 ( 0 - 3 0 L P M )
R138P11 Rev. E

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the R219P86 and is the answer not in the manual?

Questions and answers

Summary of Contents for Maxtec R219P86

  • Page 1 ACRYLIC FLOW METERS 0 - 3 0 , 0 - 7 0 & 0 - 1 2 0 L P M A S S E M B L Y I N S T R U C T I O N S &...
  • Page 3: Table Of Contents

    6.0 WARRANTY ..............6 7.0 SYMBOL GUIDE ............7 866.4.Maxtec www.maxtec.com...
  • Page 5: Product Overview

    • DO NOT connect to source pressure greater than 100 psi. • DO NOT smoke in an area where oxygen is being administered. 1.4 Cautions • Use caution to avoid cross-threading fittings during installation. • Always use a backing wrench when installing or removing connectors. 866.4.Maxtec www.maxtec.com...
  • Page 6 • ONLY use appropriate gas specific indexed fittings to connect flow meter to gas source. Use Oxygen connections for oxygen flow meters; use air connections for air flow meters. 866.4.Maxtec www.maxtec.com...
  • Page 7: Product Specifications

    NOTE: Storage/transport outside the specified range may cause damage to the flow meter. The above flow meter models are calibrated at specified inlet pressure, 70°F (21°C), standard atmospheric pressure. Specifications are subject to change without prior notice. 866.4.Maxtec www.maxtec.com...
  • Page 8: Operating Instructions

    3.0 OPERATING INSTRUCTIONS 3.1 General Operation NOTE: Maxtec strongly recommends the use of kink proof cannula. Turn knob to the “OFF” position. 2. Connect the flow meter vertically to the appropriate gas source. The appropriate gas and pressure are specified on the flow meter body.
  • Page 9: Troubleshooting

    4.0 TROUBLESHOOTING 4.1 Troubleshooting Table If the flow meter fails to function, consult your provider or Maxtec. PROBLEM CAUSE REMEDY Will not shut off • Leak • Replace seals and/or fittings • Defective valve • Replace valve Sticking float ball •...
  • Page 10: Warranty

    Maxtec or through Maxtec's designated distributors and agents as new equipment. Routine maintenance items, such as o-rings, are excluded from warranty. Maxtec and any other subsidiaries shall not be liable to the purchaser or other persons for incidental or consequential damages or equipment that has been subject to abuse, misues, mis-application, alteration, negligence or accident.
  • Page 11: Symbol Guide

    Manufacturer Representative Contains no Polyvinyl Made in USA Chloride Do Not Maxtec Toll-Free: 800.748.5355 2305 South 1070 West International: 1.801.266.5300 Salt Lake City, Utah 84119 Website: www.maxtec.com E-mail: sales@maxtec.com QNET BV Kantstraat 19 NL-5076 NP Haaren The Netherlands 866.4.Maxtec www.maxtec.com...