Adjust the memory allocation. See the Microsoft
CE Palm-size PC User's Guide.
If you have installed additional applications on your PPT
2700 terminal, remove them to recover memory.
Beamed data does not transmit:
Confirm that the PPT 2700 terminals are 5" apart, and that
the path between the two devices is clear of obstacles.
When receiving beamed data an out of memory message appears:
Your PPT 2700 terminal requires at least twice the amount of
memory available as the data you are receiving. For example,
if you are receiving a 30K application, you must have at least
60K free.
Your PPT 2700 unit does not accept scan input:
Verify that the unit is loaded with a scanning application. See
your System Administrator.
Check to be sure the bar code symbol is not defaced.
Be sure you are within proper scanning range.
Be sure the unit is programmed to accept the type of bar code
you are scanning.
If you are expecting a beep on a good decode and don't hear
one, check that the application is set to generate a beep on
good decode.
If the scanner stops emitting a laser beam when you press the
trigger, check your battery level. When the battery is low, the
scanner shuts off before the terminal notifies you of the low
battery condition.
Note:
If, after performing these checks, the scanner is still not
reading symbols, contact your distributor or Symbol
Technologies.