F262 Series Airflow Switch

Installation Instructions

Applications
IMPORTANT: Use this F262 Series Airflow Switch only as an operating control. Where failure or malfunction of
the F262 switch could lead to personal injury or property damage to the controlled equipment or other property,
additional precautions must be designed into the control system. Incorporate and maintain other devices, such as
supervisory or alarm systems or safety or limit controls, intended to warn of or protect against failure or malfunction
of the F262 switch.
IMPORTANT: Utiliser ce F262 Series Airflow Switch uniquement en tant que dispositif de régulation. Lorsqu'une
défaillance ou un dysfonctionnement du F262 switch l risque de provoquer des blessures ou d'endommager
l'équipement contrôlé ou un autre équipement, la conception du système de contrôle doit intégrer des dispositifs
de protection supplémentaires. Veiller dans ce cas à intégrer de façon permanente d'autres dispositifs, tels que
des systèmes de supervision ou d'alarme, ou des dispositifs de sécurité ou de limitation, ayant une fonction
d'avertissement ou de protection en cas de défaillance ou de dysfonctionnement du F262 switch.
The F262 Series Airflow Switch detects airflow or the absence of airflow by responding only to the velocity of air
movement within a duct. The switch can be wired to open one circuit and close a second circuit (SPDT) for either
signaling or interlock purposes.
Airflow failure during the normal operation of air handling systems may cause overheating, coil icing, or other
conditions that may be detrimental to the equipment.
Typical applications include:
make-up air systems
air cooling or heating processes
exhaust systems
The switch has a Type 3R/IP43 enclosure with an integral mounting plate. A mounting plate gasket is supplied with
each control.
The enclosed SPDT PENN switch has color-coded terminals for ease of wiring. The control is factory set at
approximately the minimum flow rate. (See Table 1) It must not be any lower than the factory setting as this may
result in the control failing to return at a no-flow condition. If a higher flow rate setting is to be maintained, turn the
range adjusting screw clockwise.
The F262 switch can be mounted on the top, side, or bottom of a duct in a horizontal position whenever possible. If
vertical duct mounting is required and the flow is downward, the control setting must be readjusted. If the flow is
upward, refer to Table 1 for minimum flow required to actuate the control.
The switch is not designed for use where it is exposed to outside weather.
Refer to the
F262 Series Airflow Switch Installation Instructions
Part No. 24-7664-2977, Rev. D
QuickLIT website
for the most up-to-date version of this document.
1
Issued September 2018

Advertisement

Table of Contents
loading

Summary of Contents for Penn F262 Series

  • Page 1: Installation Instructions

    F262 switch. The F262 Series Airflow Switch detects airflow or the absence of airflow by responding only to the velocity of air movement within a duct. The switch can be wired to open one circuit and close a second circuit (SPDT) for either signaling or interlock purposes.
  • Page 2: Installation Procedure

    3. Cut the center hole large enough for the paddle to pass through. 4. Trim the paddle, if necessary (see Figure 2). • The standard paddle fits into ducts of 3 in. × 8 in. (76 × 203 mm) minimum. F262 Series Airflow Switch Installation Instructions...
  • Page 3 When mounting the switch in a horizontal duct that is not horizontally true, check with a level and place a shim under the switch mounting plate. Do not mount the switch without a shim (see Figure 4). F262 Series Airflow Switch Installation Instructions...
  • Page 4 Turn the adjusting screw (Figure 6) clockwise until the switch closes the circuit between the red and blue terminals when there is no air flow. b. Turn the adjustment screw one additional turn clockwise. F262 Series Airflow Switch Installation Instructions...
  • Page 5: Location Considerations

    Example: On a 3 in. × 8 in. duct, mount the F261 at least 15 in. (381 mm) from the nearest bend. FLOW FLOW Dimension A must be at least five times the distance of the smallest duct dimension. Figure 7: Required Duct Distance F262 Series Airflow Switch Installation Instructions...
  • Page 6 The circuit between the red and yellow terminals closes when the required airflow velocity is reached within the duct where the switch is installed. An indicator light or signal, when connected to the blue terminal, activates when the airflow decreases or ceases. F262 Series Airflow Switch Installation Instructions...
  • Page 7: Setup And Adjustments

    Note: Do not lower the flow rate required to activate the switch, unless the flow rate required to activate the switch was raised from the factory-set flow rate. 4. Replace the enclosure cover and tighten the cover screws with 12 in•lb of torque. F262 Series Airflow Switch Installation Instructions...
  • Page 8: Checkout Procedure

    3-1/8 in. wide x 6-7/8 in. long (79 mm x 175 mm) paddle Repair Information Do not make field repairs, except for replacement of the flow paddle. For a replacement control or paddle kit, contact the nearest Johnson Controls/PENN distributor. F262 Series Airflow Switch Installation Instructions...
  • Page 9: Technical Specifications

    Technical Specifications Table 3: F262 Series Airflow Switch Electrical Ratings UL60730/UL1059 EN60730 Volts 50/60 Hz Horsepower – – – Full Load Amperes – – Locked Rotor Amperes – – Resistive Amperes Pilot Duty VA Table 4: UL Conformity Declaration Information...
  • Page 10: F262 Series Airflow Switch

    The performance specifications are nominal and conform to acceptable industry standards. For application at conditions beyond these specifications, consult Johnson Controls or PENN Refrigeration Application Engineering at 1-800-275-5676. Johnson Controls shall not be liable for damages resulting from misapplication or misuse of its products.
  • Page 11 CHINA www.penncontrols.com ® Johnson Controls and PENN are registered trademarks of Johnson Controls in the United States of America and/or other countries. All other trademarks used herein are the property of their respective owners. © Copyright 2018 by Johnson Controls. All rights reserved.

Table of Contents