Electrical information – Single Phase (continued)
1. Before installing or servicing your pump, BE CERTAIN pump power source is
disconnected.
2. Installation and electrical wiring must adhere to state and local codes. Check
appropriate community agencies, or contact local electrical and pump
professionals.
3. CALL AN ELECTRICIAN WHEN IN DOUBT. Pump should be connected to
a separate 15 amp circuit breaker or 15 amp fuse block. Plugging into existing
outlets may cause low voltage at motor, causing blown fuses, tripping of
motor overload, or burned out motor.
4. Do not connect pump to a power supply until permanently grounded. For
maximum safety, ground pump to a circuit equipped with a ground fault
interrupter device.
5. Voltage of power supply must match the voltage of the pump.
6. Before installing pump, clear sump basin of any water, debris, or sediment.
WARNING!
Sump basin must be vented in accordance with local plumbing codes.
EBARA DOMINATORS are not designed for and CANNOT be installed in
locations classified as hazardous in the National Electric Code,
ANSI/NFPA 70.