European Conformity Information
Mira Sport range of showers complies with the following European directives:
2006/95/EC Low Voltage Directive, 2004/108/EC EMC Directive.
Mira Sport range of showers are high power appliance and are subject to
conditional connection. If the main electrical supply fuse is rated less than 80
Amps, the local electricity supply company must be contacted to confirm if the
electrical supply is adequate.
Mira Sport range of showers complies with the requirements of the UK's water
regulations.

Plumbing

Minimum Dynamic Pressure
Maximum Static Pressure
Minimum Static Pressure
Maximum Inlet Temperature
Minimum Inlet Temperature
Inlet Connection
Maximum Water Hardness
Outlet Connection

Electrical

Nominal Power at 230 V ac
Nominal Power at 240 V ac
Recommended MCB Rating
Maximum Supply Cable Size
Recommended RCD Rating
Recommended Isolator Switch
Appliance Sealing Rating
Maximum Ambient Temperature
Minimum Ambient Temperature

Dimensions

Height
Width
Depth

SPECIFICATIONS

Sport 7.5
70 kPa
(0.7 bar)
1/2" BSP Male / 15 mm Compression Fitting
Sport 7.5
6.9 kW
7.5 kW
40 A
45 A double-pole with 3 mm contact separation
IP X4 - Suitable for installation in Zone 1
7
Variant
Sport 9.0
70 kPa
(0.7 bar)
1000 kPa (10 bar)
20 kPa (0.2 bar)
30°C
2°C
200 ppm CaCO
1/2" BSP Male
Variant
Sport 9.0
8.3 kW
9.0 kW
40 A
16 mm²
30 mA tripping current
30°C
2°C
340 mm
204 mm
80 mm
Sport 9.8
70 kPa
(0.7 bar)
3
Sport 9.8
9.0 kW
9.8 kW
45 A