Advertisement

FlowVis
FlowVis
®
®
Flow Meter
IMPORTANT NOTE: For the most up-to-date version of this manual, please visit www.h2fl ow.net/product-literature
2.5" / DN50/65, 3" / DN80 and
4" / DN100 models
FlowVis® retrofi t model
www.h2fl ow.net • Tel: 888-635-0296 (Toll Free)
DESCRIPTION
FlowVis® is a revolutionary, patented solution for accurate and
reliable fl ow rate measurement in fresh water applications
such as swimming pools, spas, fountains, water features, and
solar systems.
Using a design that is based on 'mass fl ow' principles, the
FlowVis® provides many benefi ts that include:
Ease of installation without the need to have 15x of
straight pipe
Installation fl exibility that allows orientation in any
position, e.g., horizontal, vertical or even upside-down
Long life without sticking fl oats or paddle wheels
Combined Flow Meter and Check Valve in all models
except FV-C-S, FV-C-Saline, FV-3, FV-L-DN80, FV-4 and
FV-L-DN100.
CONCEPT
As fl ow increases, the check valve or safety fl apper moves
forward toward its fully open position. The fl apper's angular
position is directly related to fl ow rate through the valve body
/ Tee. A calibrated scale on the valve's lid provides a highly
accurate reading of the fl ow rate.
Flow
(+1) 419-841-7774 (International)
OR
English
Rev.4.5
Operating Manual
Calibrated Scale

Advertisement

Table of Contents
loading

Summary of Contents for H2flow FlowVis FV-C

  • Page 1 FlowVis FlowVis ® English ® Rev.4.5 Flow Meter Operating Manual IMPORTANT NOTE: For the most up-to-date version of this manual, please visit www.h2fl ow.net/product-literature DESCRIPTION FlowVis® is a revolutionary, patented solution for accurate and reliable fl ow rate measurement in fresh water applications such as swimming pools, spas, fountains, water features, and solar systems.
  • Page 2: Table Of Contents

    General Information Warranty TABLE OF CONTENTS Warranty ................15 Warranty Description ............front cover Notes ..............back cover Concept ...............front cover Contact Info ............back cover General Info Resources ................2 Service Repair Kit ............... 2 RESOURCES Models & Compatibility Thank you for purchasing the H2fl ow FlowVis® fl ow Models ...................
  • Page 3: Models & Compatibility

    FV-P-R-15 1.5” Retrofit for existing Praher® check valve body FV-H-R 2” or 2.5” Retrofit for existing Hayward® check valve body FV-H-R-15 1.5” Retrofit for existing Hayward® check valve body TABLE 3 www.h2flow.net • Tel: 888-635-0296 (Toll Free) (+1) 419-841-7774 (International)
  • Page 4: Compatibility

    Heater Chlorinator NOTE: The above graphic only relates to applications that use erosion style chemical feeders. In all other circumstances, the FlowVis® can be installed in any of the locations shown. www.h2flow.net • Tel: 888-635-0296 (Toll Free) (+1) 419-841-7774 (International)
  • Page 5: Warnings & Safety

    Warnings & Safety WARNINGS & SAFETY Check Valves should always be installed in accordance with the original manufacturer’s instructions. When purchased as a complete Check Valve & Flow Meter combination, a copy of these instructions will be included with the FlowVis® packaging.
  • Page 6: Dimensions

    Dimensions DIMENSIONS Models: FV-C-15 / FV-C-15-L DIMENSION VALUE 6.5” 5.875” Schedule 40 - 1.5” 1.375” 4.63” 3.75” WEIGHT 1.5 lbs Models: FV-C / FV-C-L / FV-C-S / FV-C-S-L / FV-C-Saline DIMENSION VALUE 6.5” 5.875” Schedule 40 - 2” (Slip) & 2.5” (with coupling) 1.375”...
  • Page 7 Dimensions Models: FV-3 / FV-3-L DIMENSION VALUE 8.0” 9.5” Schedule 80 - 3” 1.875” 4.5” 4.25” WEIGHT 3 lbs Models: FV-L-DN80 DIMENSION VALUE 203.2 mm 241.3 mm Schedule 80 - DN80 47.63 mm 114.3 mm 107.96 mm WEIGHT 1.36 kg Models: FV-4 / FV-4-L DIMENSION VALUE...
  • Page 8: Installation

    (8) screws holding the lid in place and rotate the entire lid assembly by 180˚. NOTE: Always remove the FlowVis® lid assembly prior to gluing in the valve body. www.h2flow.net • Tel: 888-635-0296 (Toll Free) (+1) 419-841-7774 (International)
  • Page 9: Lid Assembly & Operation

    10 / 20 40 / 80 FV-C-L-DN50/65 DN50/65 2” / 2.5” / FV-C-S, FV-C-S-L DN50/65 FV-3, FV-3-L, FV-L-DN80 3” / DN80 FV-4, FV-4-L, FV-L-DN100 4” / DN100 160 1136 FV-C-Saline 2” www.h2flow.net • Tel: 888-635-0296 (Toll Free) (+1) 419-841-7774 (International)
  • Page 10: Head Loss Data

    Flow Rate GPM Head Loss (FV-C-S): FlowVis Head Loss (ft H O) - 2" Schedule 40 Pipe FlowVis Head Loss (psi) - 2" Schedule 40 Pipe Flow Rate GPM Flow Rate GPM www.h2flow.net • Tel: 888-635-0296 (Toll Free) (+1) 419-841-7774 (International)
  • Page 11 FlowVis Head Loss (psi) - 4" Schedule 80 Pipe FlowVis Head Loss (ft H O) - 4" Schedule 80 Pipe Flow Rate GPM Flow Rate GPM NOTE: One 90� elbow equals 11.4 feet www.h2flow.net • Tel: 888-635-0296 (Toll Free) (+1) 419-841-7774 (International)
  • Page 12: Operation

    Operation & Maintenance OPERATION The FlowVis® is factory-calibrated to be extremely accurate across its full operating range. Any perceived ‘inaccuracy’ is related to the viewing angle at which the scale is being read. To avoid so-called ‘parallax error’, it is important to position your eye so that you are looking squarely at the tip of the indicator arm.
  • Page 13: Maintenance

    Replace spring pump running Repair chlorinator, order FlowVis® Service Repair Kit. Consider moving Flapper seal crinkled Chlorinator check valve failure FlowVis® to a different location (see ‘Chlorine Feeders’ section on pg. 4). www.h2flow.net • Tel: 888-635-0296 (Toll Free) (+1) 419-841-7774 (International)
  • Page 14: Technical Data

    Average: 98.6% in straight pipe Min / Max operating ambient temp All models 32˚F (0˚C) / 140˚F (60˚C) Periodic calibration All models None required Design life All models Greater than 5 years www.h2flow.net • Tel: 888-635-0296 (Toll Free) (+1) 419-841-7774 (International)
  • Page 15: Warranty

    It is the customer’s responsibility to ensure that the packaging used to return equipment to H2flow Controls Inc is the same, or has equivalent protective qualities, to that used to ship the product to the customer in the first instance.
  • Page 16: Notes

    Notes NOTES H2flow Controls, Inc., 3545 Silica Road, Unit F, Sylvania, OH 43560 U.S.A. Tel: 888-635-0296 (Toll Free) (+1) 419-841-7774 (International) • Fax: 419-517-9900 For international sales and service, please visit our website: www.h2flow.net Release 4.5 12/17 English...