1.3. Error display
See the following table for each "Error information" display and its contents (status).
Display order is ①②③④⑤⑥⑦ .
Condition
①
Sub-µcom
No response from Sub-µcom
NG
No response from DIR
②
DIR NG
When DSP boot, executing DSP reset makes no change to DSP1 FLAG0
③
DSP1 NG
port "H".
No change to DSP1 FLAG0 port "H" before issuing DSP command.
When DSP data read, executing WRITE="L" makes no change to ACK="H". " □ DSP1 □ ERROR □03□ □ "
When DSP data read, executing REQ="L" makes no change to ACK="L".
When DSP data write, executing WRITE="H" makes no change to ACK="H".
When DSP data write, executing REQ="L" makes no change to ACK="L".
When DSP special code boot, executing DSP reset makes no change to
DSP1 FLAG0 port "H".
No change to DSP1 FLAG0 port "H" before issuing DSP special read com-
mand.
No change to DSP1 FLAG0 port "H" before DSP version read.
When DSP boot, executing DSP reset makes no change to DSP2 FLAG0
④
DSP2 NG
port "H".
No change to DSP2 FLAG0 port "H" before issuing DSP command.
When DSP data read, executing WRITE="L" makes no change to ACK="H". " □ DSP2 □ ERROR □03□ □ "
When DSP data read, executing REQ="L" makes no change to ACK="L".
When DSP data write, executing WRITE="H" makes no change to ACK="H".
When DSP data write, executing REQ="L" makes no change to ACK="L".
When DSP special code boot, executing DSP reset makes no change to
DSP2 FLAG0 port "H".
No change to DSP2 FLAG0 port "H" before issuing DSP special read com-
mand.
No change to DSP2 FLAG0 port "H" before DSP version read.
When DSP boot, executing DSP reset makes no change to DSP3 FLAG0
⑤
DSP3 NG
port "H".
No change to DSP3 FLAG0 port "H" before issuing DSP command.
When DSP data read, executing WRITE="L" makes no change to ACK="H". " □ DSP3 □ ERROR □03□ □ "
When DSP data read, executing REQ="L" makes no change to ACK="L".
When DSP data write, executing WRITE="H" makes no change to ACK="H".
When DSP data write, executing REQ="L" makes no change to ACK="L".
When DSP special code boot, executing DSP reset makes no change to
DSP3 FLAG0 port "H".
No change to DSP3 FLAG0 port "H" before issuing DSP special read com-
mand.
No change to DSP3 FLAG0 port "H" before DSP version read.
⑥
Error appeared in EEPROM checksum.(*** is a block address number.)
EEPROM NG
⑦
Both SUB/DSP
/EEPROM OK
State
19
AVR-4810CI/AVR-4810
Display
"□SUB□ □ERROR□01□□"
"□DIR□ □ERROR□01□□"
" □ DSP1 □ ERROR □01□ □ "
" □ DSP1 □ ERROR □02□ □ "
" □ DSP1 □ ERROR □04□ □ "
" □ DSP1 □ ERROR □05□ □ "
" □ DSP1 □ ERROR □06□ □ "
" □ DSP1 □ ERROR □11□ □ "
" □ DSP1 □ ERROR □12□ □ "
" □ DSP1 □ ERROR □13□ □ "
" □ DSP2 □ ERROR □01□ □ "
" □ DSP2 □ ERROR □02□□ "
" □ DSP2 □ ERROR □04□ □ "
" □ DSP2 □ ERROR □05□ □ "
" □ DSP2 □ ERROR □06□ □ "
" □ DSP2 □ ERROR □11□ □ "
" □ DSP2 □ ERROR □12□ □ "
" □ DSP2 □ ERROR □13□ □ "
" □ DSP3 □ ERROR □01□ □ "
" □ DSP3 □ ERROR □02□ □ "
" □ DSP3 □ ERROR □04□ □ "
" □ DSP3 □ ERROR □05□ □ "
" □ DSP3 □ ERROR □06□ □ "
" □ DSP3 □ ERROR □11□ □ "
" □ DSP3 □ ERROR □12□ □ "
" □ DSP3 □ ERROR □13□ □ "
"□E2PROM□ERR***□ □"
(No error display, version display