1.3. Error display
See the following table for each "Error information" display and its contents (status).
Display order is ①②③④⑤⑥⑦ .
Condition
Sub-µcom
No response from Sub-µcom
NG
No response from DIR
DIR NG
When DSP boot, executing DSP reset makes no change to DSP1 FLAG0
DSP1 NG
port "H".
No change to DSP1 FLAG0 port "H" before issuing DSP command.
When DSP data read, executing WRITE="L" makes no change to ACK="H". " □ DSP1 □ ERROR □03□ □ "
When DSP data read, executing REQ="L" makes no change to ACK="L".
When DSP data write, executing WRITE="H" makes no change to ACK="H".
When DSP data write, executing REQ="L" makes no change to ACK="L".
When DSP special code boot, executing DSP reset makes no change to
DSP1 FLAG0 port "H".
No change to DSP1 FLAG0 port "H" before issuing DSP special read com-
mand.
No change to DSP1 FLAG0 port "H" before DSP version read.
When DSP boot, executing DSP reset makes no change to DSP2 FLAG0
DSP2 NG
port "H".
No change to DSP2 FLAG0 port "H" before issuing DSP command.
When DSP data read, executing WRITE="L" makes no change to ACK="H". " □ DSP2 □ ERROR □03□ □ "
When DSP data read, executing REQ="L" makes no change to ACK="L".
When DSP data write, executing WRITE="H" makes no change to ACK="H".
When DSP data write, executing REQ="L" makes no change to ACK="L".
When DSP special code boot, executing DSP reset makes no change to
DSP2 FLAG0 port "H".
No change to DSP2 FLAG0 port "H" before issuing DSP special read com-
mand.
No change to DSP2 FLAG0 port "H" before DSP version read.
When DSP boot, executing DSP reset makes no change to DSP3 FLAG0
DSP3 NG
port "H".
No change to DSP3 FLAG0 port "H" before issuing DSP command.
When DSP data read, executing WRITE="L" makes no change to ACK="H". " □ DSP3 □ ERROR □03□ □ "
When DSP data read, executing REQ="L" makes no change to ACK="L".
When DSP data write, executing WRITE="H" makes no change to ACK="H".
When DSP data write, executing REQ="L" makes no change to ACK="L".
When DSP special code boot, executing DSP reset makes no change to
DSP3 FLAG0 port "H".
No change to DSP3 FLAG0 port "H" before issuing DSP special read com-
mand.
No change to DSP3 FLAG0 port "H" before DSP version read.
Error appeared in EEPROM checksum.(*** is a block address number.)
EEPROM NG
Both SUB/DSP
/EEPROM OK
State
19
AVR-4810CI/AVR-4810
Display
"□SUB□ □ERROR□01□□"
"□DIR□ □ERROR□01□□"
" □ DSP1 □ ERROR □01□ □ "
" □ DSP1 □ ERROR □02□ □ "
" □ DSP1 □ ERROR □04□ □ "
" □ DSP1 □ ERROR □05□ □ "
" □ DSP1 □ ERROR □06□ □ "
" □ DSP1 □ ERROR □11□ □ "
" □ DSP1 □ ERROR □12□ □ "
" □ DSP1 □ ERROR □13□ □ "
" □ DSP2 □ ERROR □01□ □ "
" □ DSP2 □ ERROR □02□□ "
" □ DSP2 □ ERROR □04□ □ "
" □ DSP2 □ ERROR □05□ □ "
" □ DSP2 □ ERROR □06□ □ "
" □ DSP2 □ ERROR □11□ □ "
" □ DSP2 □ ERROR □12□ □ "
" □ DSP2 □ ERROR □13□ □ "
" □ DSP3 □ ERROR □01□ □ "
" □ DSP3 □ ERROR □02□ □ "
" □ DSP3 □ ERROR □04□ □ "
" □ DSP3 □ ERROR □05□ □ "
" □ DSP3 □ ERROR □06□ □ "
" □ DSP3 □ ERROR □11□ □ "
" □ DSP3 □ ERROR □12□ □ "
" □ DSP3 □ ERROR □13□ □ "
"□E2PROM□ERR***□ □"
(No error display, version display
only)