How to change parameters…………………………………………………………………………………9 Alarm Buzzer and Signals..…………………………………………………………………………………9 ELECTRICAL CONNECTIONS………………………………………………………………………………..……...10 PROBE CONNECTIONS……………………………………………………………………………………..………..10 SENSOR PROBE TEMPERATURE AND RESISTANCE………………………………………………..………...10 SERVICE INSTRUCTIONS (Trouble Shooting Guide)…………………………………………………..……….11 MASTER-BILT PART NUMBERS…………………………………………………………………………..………..12 ACCESSORIES LIST………………………………………………………………………………………..…………13 SALE AND DISPOSAL……………………………………………………………………………………..……….…13 QMVM-36L, 48L WIRINGDIAGRAM ………………………………………….…………………………..……14-15 QMVM-36E WIRING DIAGRAM……………………..……………………………….…………..….….….……..16-17 QMVM-48E WIRING DIAGRAM…………………………..…………………………….…………………………18-19...
The Master-Bilt QMVM should not be positioned where it is directly exposed to rays of the sun or near a direct source of radiant heat or air flow. No HVAC return or supply air ducts may be located near case openings. This will adversely affect the case air flow and will result in poor performance.
This is important installation, operation or service information. If you ignore the message, you may damage your cabinet. The warning and safety labels shown throughout this manual are placed on your Master-Bilt Products cabinet at the factory. Follow all warning label instructions. If any warning or safety labels become lost or damaged, call your customer service department at (662) 534-9061 for replacements.
If moisture or liquid is observed around or under a Master-Bilt cabinet, an immediate investigation should be made by qualified personnel to determine the source of the moisture or liquid. The investigation made should determine if the...
ELECTRICAL WARNING Before servicing electrical components in the case make sure all power to case is off. Always use a qualified technician. STARTING PROCEDURE Start compressor and allow the case to pull down to 42 degrees or below before placing product into the QMVM.
LOADING Do not place product in the case until 2 hours after it is started. Stock cases as quickly as possible, exposing only small quantities to store temperatures for short periods of time. It is important to keep stock rotated properly so that older stock does not accumulate.
MASTER-BILT ELECTRONIC REFRIGERATION CONTROL Display Lay-out Compressor When power is first turned on to the control, the LED indicator under COMP on the display starts blinking. After one-minute delay the compressor comes on. The LED indicator stays on while compressor relay is energized.
HOW TO CHANGE THE SETPOINT HOW TO CHANGE a parameter value LIST OF PARAMETERS Here is a list of the parameters the value of which can be changed in the programming mode, as well as their ranges. Display Master-Bilt’s Parameter Symbol Range Setting Temperature Set Point SPL…SPH...
SERVICE INSTRUCTIONS (Trouble Shooting Guide) High head pressure and high back pressure: Condenser coil clogged or restricted. Condenser fan motor defective. Low back pressure and low head pressure: Restriction in system. Refrigerant undercharged. Leak in system. Pressures normal – cabinet warm: Coil blocked with frost or ice (see #4).
MASTER-BILT PART NUMBERS The table below gives Master-Bilt part numbers. Use this chart when ordering replacement parts for your QMVM cases. All quantities are one each unless otherwise noted by parentheses. Description QMVM-36E QMVM-48E QMVM-72E Shelves and overhead Ballast 23-01709...
OWNER RESPONSIBILITY If you sell or give away your Master-Bilt cabinet you must make sure that all safety labels and the Installation - Service Manual are included with it. If you need replacement labels or manuals, Master-Bilt will provide them free. Contact the customer service department at Master-Bilt at (800) 684-8988.