Eclipse RatioMatic RM Series Installation Manual page 8

Table of Contents

Advertisement

"C"
RM0050 - RM0700
Figure 3.2. Mounting Pattern
Chamber Wall
Make sure the chamber wall
support the weight of the burner
the mounting area.
If the chamber insulation extends beyond the nozzle
position of the burner, taper the insulation around the
combustor at a minimum 45° angle. Refer to Datasheets
to determine the position of the nozzle relative to the
chamber wall.
4
2
Figure 3.3. Chamber Wall
Burner Mounting
Mount burner to chamber wall using four (4 or 8) customer
supplied nuts and lock washers, as required.
Both Alloy and Silicon Carbide (SiC) Combustor
1. Be sure gasket
is installed between burner
chamber wall
.
2. Pack fiber insulation around the combustor to a depth
not beyond the nozzle position, as illustrated.
8
"C"
RM1000 - RM3000
is strong enough to
. If necessary, reinforce
45° Minimum
Chamber
Insulation
and
4
2
Figure 3.4. Alloy Combustor
■ Placing insulation around the combustor beyond
the
burner
combustor life.
3. No gasket is supplied or required between the burner
and combustor.
Silicon Carbide (SiC) Combustor Only
■ SiC combustor
If the SiC combustor is not already attached to the burner,
be sure gasket
is installed between the SiC combustor
and flange
. Tighten the screws which hold the flange
to the burner
4
3
6
Figure 3.5. Silicon Carbide (SiC) Combustor
■ When replacing SiC combustor be sure gasket
is installed, tighten screws evenly, and do not use
excessive force.
Eclipse RatioMatic Burners, RM Series, V5, Installation Guide 110, 12/3/2014
1
Fiber insulation
Chamber
insulation
CAUTION
nozzle
position
will
CAUTION
is fragile. Handle with care.
evenly. Do not over tighten.
1
5
Fiber insulation
Chamber
insulation
2
CAUTION
decrease