Honeywell enCore FC1 Instructions For Use Manual

Honeywell enCore FC1 Instructions For Use Manual

Flow computer
Hide thumbs Also See for enCore FC1:
Table of Contents

Advertisement

Flow Computer
enCore FC1
FC1-ULM-EN c 2018-02-13
Manual
Instructions for Use in Legal Metrology
2018-02-13
as of SW version 03-27-B

Advertisement

Table of Contents
loading

Summary of Contents for Honeywell enCore FC1

  • Page 1 Flow Computer enCore FC1 Manual Instructions for Use in Legal Metrology FC1-ULM-EN c 2018-02-13 2018-02-13 as of SW version 03-27-B...
  • Page 2 The manual cannot be understood as a guarantee of product properties. It also describes properties that are only available as an option. Honeywell is in no case liable to third parties for direct, special or consequential damages. The information in this document is subject to change without notice.
  • Page 3: Table Of Contents

    The enCore/enSuite Concept Honeywell (Elster GmbH) Contact Information About this Technical Documentation About the Documentation on Hand The enCore FC1 Manual at a Glance General Legal Information Legally Relevant Information at the Device Itself Additional Static Information Additional Variable Information...
  • Page 4 Software Download FC1: Legally Relevant Functionalities Basic System Gas Quality AFB Flow Conversion AFB Table Z AFB FC1: Technical Data General Inputs Outputs Interfaces for Digital Communication References Index Appendix Page 4 of 61 Use in Legal Metrology enCore FC1...
  • Page 5: General Information

    Function Blocks (abbreviated as: AFBs). Owing to this modular design principle, each device can be optimally adapted to individual requirements. The enCore FC1 belongs to the enCore Flow Computer device series (in short: enCore FC). This series comprises several different device types that are used as industrial process computers for special tasks for measuring gas and liquids.
  • Page 6: Honeywell (Elster Gmbh) Contact Information

    General Information 1.2 Honeywell (Elster GmbH) Contact Information You can contact our sales and service department at: Elster GmbH (manufacturer) Steinern Straße 19-21 55252 Mainz-Kastel/Germany Phone: +49 6134 605-0 Email: info@elster.com Website: www.elster-instromet.com You can reach our Technical Assistance Center (TAC) at:...
  • Page 7: About This Technical Documentation

    2 About this Technical Documentation 2.1 About the Documentation on Hand This technical documentation is part of the enCore FC1 manual; it briefly describes the properties of the enCore FC1 flow computer being relevant for the use of the device in legal metrology.
  • Page 8: The Encore Fc1 Manual At A Glance

    About this Technical Documentation 2.2 The enCore FC1 Manual at a Glance The FC1 manual has a modular structure; it is made up of several volumes. Apart from the documentation on hand, all other single volumes of the manual cover all devices of the enCore FC series; they are therefore independent of the device type.
  • Page 9 You can download all other volumes of the manual in PDF format from our Docuthek (www.docuthek.com). In addition, the "Instructions for Use in Legal Metrology" and the "Operating Instructions" are also available in digital form here. The documents are updated regularly. enCore FC1 Use in Legal Metrology Page 9 of 61...
  • Page 10: General Legal Information

    Table 1: Legally relevant information at the FC1 front/rear panel 3.2 Additional Static Information MPE at reference conditions 0.5 % (including AD conversion) Extreme temperatures of the Ambient temperature range −10 °C environmental class to +55 °C Page 10 of 61 Use in Legal Metrology enCore FC1...
  • Page 11: Additional Variable Information

    Compression factor calculation at the device's display (displays for algorithm fiscal parameters, please refer to Chapter 5.4.5). Gas properties Table 3: Additional variable information enCore FC1 Use in Legal Metrology Page 11 of 61...
  • Page 12: Fc1: General Information

    4 FC1: General Information 4.1 FC1: General Device Description The enCore FC1 flow computer is an electronic conversion device for meas- uring and calculating the flow of natural gas or, in special applications, indus- trial gas or gases with a fixed composition. Different measurement devices are to be connected to the flow computer (gas meters, pressure transmitters, temperature transmitters and, optionally, gas quality measurement devices).
  • Page 13 PC or laptop (Windows). When selecting the calculation standard, the regulations of the EU type-examination certificate must be observed. enCore FC1 Use in Legal Metrology Page 13 of 61...
  • Page 14: Fc1: Hardware

    Intended for the connection of gas meters (via pulses or encoder index), ultrasonic gas meters (RS485 serial interface), pressure transmitters (4 … 20 mA or HART), temperature transmitters (resistance input or HART). Page 14 of 61 Use in Legal Metrology enCore FC1...
  • Page 15: Fc1: Software

    An AFB is a single application-driven functionality that can be added or removed by parameterization. In principle, the device can use each AFB enCore FC1 Use in Legal Metrology Page 15 of 61...
  • Page 16: Fc1: Legally Relevant Software (For Use In Legal Metrology)

    Ta b l e Z A F B conversion factor C by using a parameterized compressibility factor table depending on pressure and temperature. Page 16 of 61 Use in Legal Metrology enCore FC1...
  • Page 17: Fc1: Non-Legally Relevant Afbs

    P o s t p r o c e s s i n g The DSfG specification is issued by DVGW Deutscher Verein des Gas- und Wasserfachs (“DVGW-Arbeitsblatt” G 485, „Technische Spezifikation für DSfG- Realisierungen, Gas-Information Nr. 7“). enCore FC1 Use in Legal Metrology Page 17 of 61...
  • Page 18: Fc1: Afb Structure For Common Applications

    Flow Conversion Gas quality data GQ Gas meter data GM Pressure data p Temperature data T Basic System Figure 1: Data flow for a basic “one stream, one flow direction” application Page 18 of 61 Use in Legal Metrology enCore FC1...
  • Page 19 GQ G a s Q u a l i t y A F B calculation standards and the same base conditions are to be applied to both flow directions. enCore FC1 Use in Legal Metrology Page 19 of 61...
  • Page 20 Stream 1 Stream 2 Stream 1 Stream 2 AFB FC AFB FC GMdata GMdata Stream 1 Stream 2 Basic System Figure 3: Data flow for 2 streams, 1 flow direction each Page 20 of 61 Use in Legal Metrology enCore FC1...
  • Page 21 AFB FC fd 1 AFB FC fd 2 AFB FC GMdata GMdata Stream 1 Stream 2 (incl. fd info) Basic System Figure 4: Data flow for 2 streams (dual/single fd) enCore FC1 Use in Legal Metrology Page 21 of 61...
  • Page 22: Fc1: Afb Structure For Special Applications

    G a s Q u a l i t y . The calculates the compressibility factor Zm at A F B Ta b l e Z A F B measurement conditions (p, t) by using a compressibility factor table. Page 22 of 61 Use in Legal Metrology enCore FC1...
  • Page 23: Fc1: Operation For Legally Relevant Functionalities

    Figure 5: FC1 operating controls  Navigation keys  Function keys  Touch screen  Security switch (sealable)  Power LED  Status LED   USB port for PC connection enCore FC1 Use in Legal Metrology Page 23 of 61...
  • Page 24: Keys

    Note: There are legally relevant parameters that can be changed by a user even if the security switch is closed. In that case, the action is recorded in the Fiscal Audit Trail (cf. page 43). Page 24 of 61 Use in Legal Metrology enCore FC1...
  • Page 25: Leds

    An alarm is an error event affecting the legally relevant functionalities severely; the calculation of the fiscal results is stopped. In case of a warning, a minor error has occurred but the calculation of the fiscal results is continued. enCore FC1 Use in Legal Metrology Page 25 of 61...
  • Page 26: Display And Navigation

    5.3 Display and Navigation 5.3.1 Display Test The enCore FC1 provides a display test functionality to check that the dis- play functions correctly. For starting the display test, you have to activate the  button in the device's home display at first. The information display is evoked. The display test can be started by activating the Display test hyperlink.
  • Page 27: Different Types Of Device Displays

    If an AFB has been assigned to a structuring folder in this way, the name of the related folder appears as a hint when selecting the correspond- ing button on the screen. enCore FC1 Use in Legal Metrology Page 27 of 61...
  • Page 28: Navigation Via Touch Screen

    Most displays show measurement results, status information or settings. An underlined text element always represents a hyperlink, e.g. a reference to another display showing further details. Actions are also marked as hyperlinks in the FC1 display. Page 28 of 61 Use in Legal Metrology enCore FC1...
  • Page 29: Navigation Via Keys

    F l o w C o n v e r s i o n A F B the main counter for volume at base conditions is preferentially indicated. enCore FC1 Use in Legal Metrology Page 29 of 61...
  • Page 30 Figure 8 shows an example of a Flow Conversion fiscal display; Table 10 lists the target displays of the available hyperlinks as well as the values and results included. Page 30 of 61 Use in Legal Metrology enCore FC1...
  • Page 31 Vm is displayed here in case that no gas meter correction is parameterized. In case that a gas meter correction is activated via parameterization, the corrected volume Vc is shown instead. enCore FC1 Use in Legal Metrology Page 31 of 61...
  • Page 32 If no gas meter correction is parameterized, the flow rate Qm (uncorrected flow rate at measurement conditions) is displayed instead of Qc. Within the target display, the lines for Qc and the correction factor are omitted in that case. Page 32 of 61 Use in Legal Metrology enCore FC1...
  • Page 33 Maintenance Maintenance The maintenance mode is intended mode for testing purposes; its activation requires a user login. In maintenance mode, a constant value for the flow rate Qm can be enCore FC1 Use in Legal Metrology Page 33 of 61...
  • Page 34 In addition to activating the maintenance mode via the control panel described here, a message input (parameterizable) can be used to trigger the maintenance mode. For detailed information refer to [8] or the related online help topic in enSuite. Page 34 of 61 Use in Legal Metrology enCore FC1...
  • Page 35 Encoder index and the corresponding value is explicitly parameterized for displaying in Flow Conversion AFB. The Vo counter repeats the original counter of the gas meter that is transferred via digital Encoder protocol. enCore FC1 Use in Legal Metrology Page 35 of 61...
  • Page 36: Gas Quality Afb

    Figure 10 shows a typical example of a Gas Quality main display; Table 12 lists the target displays of the hyperlinks as well as the values and measurements included. Qc is replaced by Qm if no gas meter correction is parameterized. Page 36 of 61 Use in Legal Metrology enCore FC1...
  • Page 37 Hyperlink/value Target display Values shown in target display Pressure p Temperature t Compressibility Pressure Temperature Pressure at base conditions Temperature at base conditions Conversion factor Compressibility factor at measurement conditions enCore FC1 Use in Legal Metrology Page 37 of 61...
  • Page 38 The acronyms with three letters (OOU, OOS, INT, OOO, OOC, OLL, and OUL) denote the actual reason why a level cannot be used. Error status Meaning Out Of Use Out Of Service INiTialization Page 38 of 61 Use in Legal Metrology enCore FC1...
  • Page 39 The Table Z's main display shows following values and measurements: • pressure p • temperature t • conversion factor C • Zm, compressibility factor at measurement conditions (p, t) enCore FC1 Use in Legal Metrology Page 39 of 61...
  • Page 40: Error List And Logbook

    There is a filter option for displaying errors of single function blocks only or of function blocks that are grouped by parameterization.       Figure 12: Error List display (example) Page 40 of 61 Use in Legal Metrology enCore FC1...
  • Page 41 The Logbook display can be evoked by activating the related button within the Error list display. Whenever an error becomes active or ends, its state change is recorded in the logbook.    Figure 13: Logbook display (example) enCore FC1 Use in Legal Metrology Page 41 of 61...
  • Page 42: Software Identification/List Of Fiscal Parameters

    These displays enable the user to check all legally relevant set- tings directly at the device. For better identification, the checksums of all legally relevant software parts are highlighted and marked with a special preceding icon Page 42 of 61 Use in Legal Metrology enCore FC1...
  • Page 43: Fiscal Audit Trail

    Activate the System button in the home display. • Activate the button labeled Audit trail. • Select “Fiscal” in the drop down list at the left    Figure 14: Audit trail display (example) enCore FC1 Use in Legal Metrology Page 43 of 61...
  • Page 44 Scroll bar (only if more than one entry is available) If the fiscal audit trail contains more than one entry, it is also possible to use the navigation keys to page through the audit trail entries. Page 44 of 61 Use in Legal Metrology enCore FC1...
  • Page 45: Usb Port For Pc Connection

    You can only erase the fiscal audit trail, if the security switch is open. Such parameters (marked ) are called secured parameters. enCore FC1 Use in Legal Metrology Page 45 of 61...
  • Page 46 If the FC1 detects that the securing mechanism for at least one parameter in the parameterization is weaker than specified in the approval file of the device software, the identifying Page 46 of 61 Use in Legal Metrology enCore FC1...
  • Page 47: Software Download

    AFB configuration are prohibited if the device's security switch is closed. Please refer to the related chapter in the volume “Configuration of Device Software” of the enCore FC1 manual or the enSuite online help for further details. enCore FC1...
  • Page 48: Fc1: Legally Relevant Functionalities

    • Status, error information Temperature • Measurement, adjusted measurement transmitter • Status, error information Gas quality • Measurements measurement device • Status, error information Table 13: Legally relevant measurement data Page 48 of 61 Use in Legal Metrology enCore FC1...
  • Page 49: Gas Quality Afb

    G a s Q u a l i t y A F B calculation standards that are not admitted for use in legal metrology. When selecting the calculation standard, the regulations of the EU type-examination certificate must be observed. enCore FC1 Use in Legal Metrology Page 49 of 61...
  • Page 50 Message generation (derived from monitoring of input Ø measurements) Export values C, Zm, Zb, K, p, t, ρm, ρb, HM, HV,…. for further processing Gas Quality AFB Figure 16: Data flow for Gas Quality AFB Page 50 of 61 Use in Legal Metrology enCore FC1...
  • Page 51: Flow Conversion Afb

    G a s Q u a l i t y A F B the meter correction and the counter administration due to error handling and – if applicable – takes the counter activation message (e.g. for flow direction switching) into consideration. enCore FC1 Use in Legal Metrology Page 51 of 61...
  • Page 52 Export values: counters, flow rates, measurements…. Flow Conversion AFB Figure 17: Data flow for F l o w C o n v e r s i o n A F B Page 52 of 61 Use in Legal Metrology enCore FC1...
  • Page 53 Qc= Qm* Cf where volume at measurement conditions volume at measurement conditions, gas meter correction applied flow rate at measurement conditions flow rate at measurement conditions, gas meter correction applied correction factor enCore FC1 Use in Legal Metrology Page 53 of 61...
  • Page 54 As long as liquid state is detected, an alarm is pending. At the same time, the Zm, K and C results are marked as being in error and the C result is set to zero (0). Page 54 of 61 Use in Legal Metrology enCore FC1...
  • Page 55: Fc1: Technical Data

    480 × 272 × 3 pixels, LED background lighting 4 navigation and 2 function keys 2 multicolor LEDs for power and status indication Sealable security switch Table 14: General technical data enCore FC1 Use in Legal Metrology Page 55 of 61...
  • Page 56: Inputs

    4 transmitters with HART interface (1 trans- mitter in burst mode or up to 4 transmitters in multidrop mode) • input for a Pt100 temperature sensor in 4-wire technology Table 15: Inputs: Technical specifications Page 56 of 61 Use in Legal Metrology enCore FC1...
  • Page 57: Outputs

    USB interface for PC or laptop connection for parameterization and service purposes Ethernet • NTP, Modbus TCP, FTP, HTTP communication Serial communication • Modbus (ASCII, RTU), UNIFORM Table 17: Communication interfaces: Technical specifications enCore FC1 Use in Legal Metrology Page 57 of 61...
  • Page 58: References

    [6] Manual „Flow Computer, Device series enCore FC – Basic System with SFBs“ available for download at www.docuthek.com [7] Manual „Flow Computer enCore FC1 – Gas Quality AFB“ available for download at www.docuthek.com [8] Manual „Flow Computer enCore FC1 – Flow Conversion AFB“...
  • Page 59: Index

    Keys 24 enCore 5 enSuite 5 Error list 40 LEDs 25 ESER4 15, 57 List of fiscal parameters 42 Ethernet 57 Logbook 41 EU Type Examination Certificate Appendix European standards 13 enCore FC1 Use in Legal Metrology Page 59 of 61...
  • Page 60 Display 39 Technical data 55 Touch screen 24 Parameterization 13, 45 Type plate 10 Physical quantities Symbols 29 Power LED 25 USB port 45, 57 Power supply 55 Preprocessing display 38 Page 60 of 61 Use in Legal Metrology enCore FC1...
  • Page 61: Appendix

    Appendix 10 Appendix • EU Type Examination Certificate (NMi) • FC1: Markings and Device Sealing enCore FC1 Use in Legal Metrology Page 61 of 61...
  • Page 71 Front markings for an FC1 with 1/3 housing width, Honeywell front design Type plates Front markings for an FC1 with 1/2 housing width, Elster or Honeywell front design Front Sealing Rear Sealing Sealing of Process Connectors PAGE: 1 OF 12...
  • Page 72: Fc1 Front Markings

    1/3 for up to four process boards or a housing width of 1/2 for up to seven process boards. The front plate for both housing widths is available in two designs (Elster or Honeywell). 1.1 Front markings for an FC1 with 1/3 housing width,...
  • Page 73: Front Markings For An Fc1 With 1/3 Housing Width, Honeywell Front Design

    1.2 Front markings for an FC1 with 1/3 housing width, Honeywell front design Figure 2: FC1 front view with position of type plates (1/3 housing width, Honeywell design)  Location of type plate part 1  Location of type plate part 2 ...
  • Page 74: Type Plates

    1.3 Type plates For the design of the type plates there are two alternatives differing slightly in label size and arrangement. Figure 3 shows the first and Figure 4 the second alternative. In the second alternative, a 2D code can be applied on the left part of the type plate optionally.
  • Page 75: Front Markings For An Fc1 With 1/2 Housing Width, Elster Or Honeywell Front Design

    Figure 5 and Figure 6 show the FC1 front markings for both Elster and Honeywell design in case of a device with a housing width of 1/2. As there is more free space on the front plate in 1/2 housing width, the exact positioning of the type plates in practice may also deviate from Figure 5 or Figure 6.
  • Page 76 Figure 6: FC1 front view (1/2 housing width, Honeywell design)  Type plate part 1  Type plate part 2  Securing marks (adhesive labels) PAGE: 6 OF 12 DOCUMENT: FC1: MARKINGS AND DEVICE SEALING...
  • Page 77: Front Sealing

    2 Front Sealing Figure 7: FC1 device sealing, front view (1/3 housing width), exemplary for Honeywell design (same for Elster design)  Security switch (sealable)  Seal screw  Wire and seal  Securing mark (adhesive label), securing a housing screw ...
  • Page 78: Rear Sealing

    adhesive label for securing the housing screw in the top left corner of the   front and adhesive label for securing the type plates 3 Rear Sealing Figure 8 and Figure 9 show the FC1 rear view for both housing types, the process board configuration being typical examples that may differ from application to application.
  • Page 79 Figure 9: FC1 device sealing, rear view (1/2 housing width, typical process board configuration)  Securing marks (adhesive labels), securing two of the housing screws at the rear The connectors of the process boards that are applied for legally relevant purposes are to be sealed as described in Chapter 4.
  • Page 80: Sealing Of Process Connectors

    4 Sealing of Process Connectors For fiscal use, the connectors of legally relevant process boards have to be officially secured. Plug-in connectors with screws are used for connecting the lines of the ExMFE5 and the MFE7 board. Sealing of ExMFE5 connectors In case of an ExMFE5 board, there is only one connector for all lines.
  • Page 81 Figure 11 (schematic): Sealing of ExMFE5 plug-in connectors with adhesive labels (view from below and from above, cable feeding from below or from above, depending on installation situation)  Sensor and transmitter lines  Connector housing  Rear panel  Securing mark (adhesive labels) Sealing of MFE7 connectors In case of an MFE7 board, there are two connectors for connecting all...
  • Page 82 Sealing of RJ45 connectors RJ45 connectors for digital interfaces as provided by the CPU board and the MSER4 board can be secured by securing marks in form of adhesive labels. PAGE: 12 OF 12 DOCUMENT: FC1: MARKINGS AND DEVICE SEALING...

Table of Contents