ECE directive
The IE switch SCALANCE X005TS meets the requirements of the directive ECE R10,
Rev. 3.
EC directive
The SCALANCE X005TS IE switch meets the requirements of the Directive 72/245/EEC in
the form 2006/96/EC "Electromagnetic Compatibility".
8.5

Noise test of the SCALANCE X005TS

The IE switch SCALANCE X005TS was tested according to EN 60068-2-64.
Testing accuracy:
Severity level:
8.6

Overvoltage test of the SCALANCE X005TS

The SCALANCE X005TS IE switch has passed further overvoltage tests.
Power supply = 24 VDC
Overvoltage test with:
● 36 V/1s
● 100 V/1ms (with a source resistance of 10 ohms)
8.7

Mechanical stability (in operation)

Device
X005
X005 TS
SCALANCE X005 / X005TS
Operating Instructions, 07/2014, C79000-G8976-C344-01
IEC 60721-3-5
Class 5M2 (for road vehicles)
DIN EN 60068-2-6 oscillation
10 - 58.12 Hz: 0.075 mm
58.12 - 500 Hz: 10 m/s
2
10 cycles
8.5 Noise test of the SCALANCE X005TS
DIN EN 60068-2-27 shock
150 m/s
, 11 ms duration
2
6 shocks per axis