4. EXPLOITATION

Temperature of the cooled space and aggregate operating cycle may fl uctuate. They depend on numerous factors,
such as amount and temperature of products placed in the device and temperature of the surroundings.
The device should be placed in a dry and well-ventilated place, ensuring proper air exchange (distance between the
wall and the device – min. 10 cm), out of sunlight, kept far from heat sources and devices enforcing air fl ow (ceiling
and portable ventilators, blow-in heaters). The device functions properly in a room, where temperature falls within
appropriate climatic class stated on the data plate. The operation of the device may worsen when it shall operate in
temperature lower or higher than the stated temperature range.
Remarks and indications
• It is necessary to properly level the display cabinet, which will prevent loud operation of the device and
shall ensure proper water (condensate) outfl ow during defrosting.
• After transporting the device, wait about 2 hours before its actuation.
• The fi rst fi lling of cooling space should be performed after its previous cooling to working temperature.
This principle should also be observed after longer pause in exploitation.
• Do not block any ventilation holes, which would hamper circulation of the cooled air. It is also necessary
to ensure proper airfl ow around the device (aggregate ventilation holes cannot be covered!!!!).
• Keep the condenser clean. Impurities may lead to overheating of the compressor and as a consequence
may result in damage of the device, which is not covered by warranty.
• Do not use electric devices inside grocery product storing chamber.
• In case when the device is being exploited without the need to display goods (night work; closed stand,
cake shop) it is necessary to roll down the roller in the cabinet in order to decrease electric energy
consumption!

Fig.8 Front pane lifted improperly

4.1. Temperature regulation

Service of "Igloo" and "Carel" thermostat (temperature regulators) is described in chapter 7 (p.19 and 20)
The basic aim of a thermostat is to control the cooling aggregate to obtain the set temperature within the device and
maintain it within the determined temperature ranges. The producer enters all settings of temperature regulators required
for normal functioning of the device. Before primary actuation the user should control and possibly set the required tem-
perature inside the device on the control panel.
Digital display – displays the current temperature inside the device.
It is forbidden to interfere with systemic parameters of the thermostat, as this can lead to serious consequ-
ences, including the damage of the cooling device!
www.igloo.pl
In devices with the system of lifted panes,
it is not allowed to lift both panes (within a
single module) at the same time. It is also
forbidden for both panes to be left in their lifted
position at the same time. Fig. 8 (page 15). This
refers both to washing and operating the device!