Daikin BRP069A61 Installer's Reference Manual

Daikin BRP069A61 Installer's Reference Manual

Altherma lan adapter
Hide thumbs Also See for BRP069A61:
Table of Contents

Advertisement

Installer reference guide
Daikin Altherma LAN adapter
Installer reference guide
BRP069A61
English
Daikin Altherma LAN adapter
BRP069A62

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BRP069A61 and is the answer not in the manual?

Questions and answers

Summary of Contents for Daikin BRP069A61

  • Page 1 Installer reference guide Daikin Altherma LAN adapter Installer reference guide BRP069A61 English Daikin Altherma LAN adapter BRP069A62...
  • Page 2: Table Of Contents

    Overview: Configuration ............14 Daikin website (publicly accessible). Configuring the LAN adapter for app control......14 ▪ The full set of latest technical data is available on the Daikin Configuring the LAN adapter for the Smart Grid application ..14 extranet (authentication required).
  • Page 3: Compatibility

    Status LEDs Status LEDs Compatibility Description Behaviour Make sure your Daikin Altherma system is compatible for use with Indication of power to the ▪ LED flashing: normal the LAN adapter (app control and/or Smart Grid applications). For adapter, and of normal operation.
  • Page 4: App Control (Only)

    2 About the product 2.2.1 App control (only) P1/P2 LAN adapter (BRP069A61/BRP069A62) User interface Indoor unit Router Installer reference guide BRP069A61+BRP069A62 Daikin Altherma LAN adapter 4P464229-1B – 2018.10...
  • Page 5: Smart Grid Application (Only)

    2 About the product 2.2.2 Smart Grid application (only) P1/P2 230 V AC LAN adapter (BRP069A61) Solar inverter/energy management system Indoor unit Circuit breaker User interface Solar panels Electricity meter (optional) BRP069A61+BRP069A62 Installer reference guide Daikin Altherma LAN adapter 4P464229-1B – 2018.10...
  • Page 6: App Control + Smart Grid Application

    2 About the product 2.2.3 App control + Smart Grid application P1/P2 230 V AC LAN adapter (BRP069A61) Indoor unit User interface Router Electricity meter (optional) Solar inverter/energy management system Circuit breaker Solar panels Installer reference guide BRP069A61+BRP069A62 Daikin Altherma LAN adapter...
  • Page 7: System Requirements

    3 About the box INFORMATION System requirements ▪ For an overview of the possible system layouts, see The requirements posed on the Daikin Altherma system depend on "2.2  System layout"  on page  3. For more information the LAN adapter application/system layout.
  • Page 8: Preparation 8

    All wiring to X1A MUST be H05VV. Required strip length: Provide enough space to open the casing with a flat-blade 7 mm. For more information, see "4.2.4 Solar inverter/ screwdriver (typically 160 mm) energy management system" on page 9. Installer reference guide BRP069A61+BRP069A62 Daikin Altherma LAN adapter 4P464229-1B – 2018.10...
  • Page 9: Router

    Connector X1A is for the connection of the LAN adapter to the digital Power line outputs of a solar inverter/energy management system, and allows for the integration of the Daikin Altherma system in a Smart Grid application. X1A/N+L supply a 230 V AC detection voltage to the input contact of X1A.
  • Page 10: Installation

    ▪ It is NOT allowed to route wiring from the bottom, clamp it between the casing and the wall, and let it enter via the holes in the rear (c). Installer reference guide BRP069A61+BRP069A62 Daikin Altherma LAN adapter 4P464229-1B – 2018.10...
  • Page 11: To Mount The Pcb To The Rear Casing

    ▪ Connecting the adapter to an electricity meter (optional). 2 Connect indoor unit terminals P1/P2 to LAN adapter terminals X3A/1+2. For more information about the Smart Grid application, see "8 Smart Grid application" on page 17. BRP069A61+BRP069A62 Installer reference guide Daikin Altherma LAN adapter 4P464229-1B – 2018.10...
  • Page 12: To Connect The Router

    (Smart Grid application), connect the digital outputs of the the indicated cable path. solar inverter/energy management system to LAN adapter digital inputs X1A/1+2 LAN. 2 Connect the electricity meter to LAN adapter terminals X2A/1+2. Installer reference guide BRP069A61+BRP069A62 Daikin Altherma LAN adapter 4P464229-1B – 2018.10...
  • Page 13: Finishing The Lan Adapter Installation

    After powering on the system, it can take up to 30 minutes before the LAN adapter is operational, depending on the system layout. BRP069A61+BRP069A62 Installer reference guide Daikin Altherma LAN adapter 4P464229-1B – 2018.10...
  • Page 14: Configuration

    LAN adapter configuration depends on the LAN adapter application/ system layout. Updating software Then To update LAN adapter software, use the Daikin Online Controller The LAN adapter is used for app "7.2 Configuring the LAN app. control adapter for app control" on page 14.
  • Page 15: Accessing The Configuration Web Interface

    To retrieve the LAN adapter's IP address, various ways are possible: Serial number Serial number Retrieval via Instruction User interface The Daikin Online Controller app ▪ In the app, go to "Adapter User interface SW User interface software information" > "IP address". User interface EEPROM User interface EEPROM ▪...
  • Page 16: Network Settings

    INFORMATION and assign a custom static IP For BRP069A61, 'power' is both the power supplied by the address to the LAN adapter. Do indoor unit AND the 230  V  AC detection voltage supplied this via the DIP switch. See "Via...
  • Page 17: Removal

    The solar inverter/energy management system controls the state of the LAN adapter's digital inputs. Depending on the state of the inputs Removal (open or closed), the Daikin Altherma system can run in the following Smart Grid operation modes: When you connect/disconnect the LAN adapter to/from the indoor Smart Grid operation mode unit, the system should register its presence/absence automatically.
  • Page 18: Smart Grid Settings

    In the "Recommended ON" operation mode, the power consumption INFORMATION of the Daikin Altherma system is limited either statically or dynamically. In both cases, it is possible to include the power For instructions on how to access the configuration web...
  • Page 19: Operation Modes

    ERLQ011~016 EBLQ +EDLQ011~016CA(3)V3+W1 outdoor units, the power In the "Forced ON" operation mode, the Daikin Altherma system limitation functionality is NOT available. When these makes use of solar/grid power (when it is available, as measured by outdoor units are used in a Smart Grid system, they will the solar inverter/energy management system) to produce domestic operate without power limitation.
  • Page 20: System Requirements

    NOT support DHCP. The computer is NOT connected Connect the computer to the to the same router as the LAN same router as the LAN adapter. adapter. Installer reference guide BRP069A61+BRP069A62 Daikin Altherma LAN adapter 4P464229-1B – 2018.10...
  • Page 21 30 minutes, the compatibility check failed, and NO Smart Grid operation is possible. For a complete description of the status LEDs, check "2  About the product" on page 2. BRP069A61+BRP069A62 Installer reference guide Daikin Altherma LAN adapter 4P464229-1B – 2018.10...
  • Page 22: Technical Data

    10 Technical data Technical data A subset of the latest technical data is available on the regional Daikin website (publicly accessible). The full set of latest technical data is available on the Daikin Business Portal (authentication required). 10.1 Wiring diagram...
  • Page 24 4P464229-1B 2018.10...

This manual is also suitable for:

Brp069a62

Table of Contents