5.5.1 About opening the LAN adapter........Daikin website (publicly accessible). 5.5.2 To open the LAN adapter..........▪ The full set of latest technical data is available on the Daikin 6 Configuration extranet (authentication required). Overview: Configuration ............Updating software ..............
ON or go OFF. When the LED keeps flashing for more than 30 minutes, the compatibility check failed, and NO Smart Grid operation is possible. System requirements Make sure your Daikin Altherma system is compatible for use with adapter (smartphone control...
▪ Mind the following spacing installation guidelines: To indoor unit To router Connections Connection Cable section Wires Maximum cable length Accessory cables Router (X4A) — — 50/100 m Field-supplied cables Installer reference guide BRP069A61+BRP069A62 Daikin Altherma LAN adapter 4P464229-1A – 2017.11...
Digital inputs Connector X1A is for the connection of the LAN adapter to the digital inputs of a solar inverter / energy management system, and allows for use of the Daikin Altherma system in various Smart Grid applications. BRP069A61+BRP069A62 Installer reference guide Daikin Altherma LAN adapter 4P464229-1A –...
To mount the rear casing to the wall Connecting the adapter to a router. 1 Hold the rear casing against the wall and mark the position of Connecting the adapter to an electrical meter (BRP069A61 the holes. only). Connecting the adapter to the digital outputs of a solar inverter / 2 Drill the holes.
Make sure to connect the electrical meter in the correct direction, so that it measures the total energy injected INTO the grid. 5.3.6 To connect the digital inputs INFORMATION This connection is ONLY supported by LAN adapter BRP069A61. BRP069A61+BRP069A62 Installer reference guide Daikin Altherma LAN adapter 4P464229-1A – 2017.11...
To connect to a voltage free contact (Smart Grid) If the solar inverter / energy management system has a voltage free contact, connect the LAN adapter as follows: 1× 230 V AC To voltage free contact Installer reference guide BRP069A61+BRP069A62 Daikin Altherma LAN adapter 4P464229-1A – 2017.11...
To open the LAN adapter INFORMATION 1 Remove the screw with a screwdriver. For the Daikin Altherma unit and user interface to function 2 Pull the top of the front casing towards you. with the LAN adapter, it is required that their software meets requirements.
INFORMATION Result: To implement changes, the LAN adapter automatically performs a power reset. For BRP069A61, 'power' is both the power supplied by the indoor unit AND the 230 V AC detection voltage supplied INFORMATION to X1A. After the automatic power reset, the status LEDs go ON and OFF alternately for 5 times.
(i.e. energy buffering), minimising the power injection into the grid. The amount of photovoltaic energy that When you connect the LAN adapter to the Daikin Altherma unit, the is used for buffering depends on the domestic hot water tank and/or system registers its presence automatically.
(default 1.5 kW) that is set in the configuration web interface. During energy buffering, the power It contains information about: consumption of the Daikin Altherma unit will NOT exceed this limit. ▪ Solving problems based on symptoms Dynamic power limitation ▪...
IP address to the router: 1 Set DIP switch 4 to the "ON" position and reset the adapter by turning the Daikin Altherma unit OFF and ON again. Result: adapter uses fixed address (169.254.10.10).
9 Technical data Technical data A subset of the latest technical data is available on the regional Daikin website (publicly accessible). The full set of latest technical data is available on the Daikin extranet (authentication required). Wiring diagram SD-Card 1 2 3 4 5 6 7 8...
Need help?
Do you have a question about the BRP069A61 and is the answer not in the manual?
Questions and answers