Cleaning, Maintenance, And Lubrication; Troubleshooting - Central Pneumatic 99659 Set Up And Operating Instructions Manual

12 volt / 150 psi
Table of Contents

Advertisement

ClEAnIng, MAIntEnAnCE,
And luBRICAtIOn
note: These procedures are in addition to
the regular checks and maintenance
explained as part of the regular op-
eration of the air-operated tool.
1.
WARnIng!
Make sure Power Switch
(16) of Air Compressor is in its "OFF"
position and unit is unplugged from
the vehicle's cigarette lighter socket
before performing any inspection,
maintenance, or cleaning procedures.
2.
Before each use,
condition of the Air Compressor.
Check for loose screws, misalign-
ment or binding of moving parts,
cracked or broken parts, damaged
Problem
Compressor will
1.
not start.
2.
3.
4.
5.
Low pressure.
1.
Overload
1.
Protector trips.
Severe air
1.
leakage.
(Slight air leakage
is normal,
2.
especially on older
tools.)
3.
4.
Follow all safety precautions whenever diagnosing or servicing the tool.
disconnect air supply before service.
SKU 99659
inspect general

troubleshooting

Possible Causes
Adapter (14) not securely
inserted in vehicle's cigarette
lighter socket.
Power Switch (16) not on.
Vehicle Battery not fully
charged.
Blown Adapter fuse.
Dirty or damaged brushes
Loose connection(s).
Continuous use too long.
Cross-threaded housing
components.
Loose housing.
Damaged valve or housing.
Dirty, worn or damaged valve.
For technical questions, please call 1-800-444-3353.
electrical wiring, loose air fittings, and
any other condition that may affect
the safe operation of the Compressor.
If abnormal noise or vibration occurs,
have the problem corrected before
further use. do not use damaged
equipment.
3.
to clean,
wipe with a clean, damp
cloth and a mild detergent. Then dry.
Do not use solvents. Do not immerse
the unit in liquids.
4.
to replace Adapter (14) fuse,
screw and remove the cap on the
Cigarette Lighter Adapter. Remove
the old Fuse, and replace with a new
Fuse (type: 20 Amp). Then, screw
the cap back onto the Cigarette
Lighter Adapter.
likely Solutions
1.
Insert Adapter securely.
2.
Turn on Power Switch.
3.
Charge vehicle Battery.
4.
Replace fuse (20 Amp) in Adapter.
5.
Inspect, repair or replace brushes.
1.
Make sure all connections are tight.
1.
Do not use unit continuously for over 12
minutes. Allow 30 minutes for unit to cool
down after each use.
1.
Check for incorrect alignment and uneven
gaps. If cross-threaded, disassemble and
replace damaged parts before use.
2.
Tighten housing assembly. If housing cannot
tighten properly, internal parts may be
misaligned.
3.
Replace damaged components.
4.
Clean or replace valve assembly.
un-