Reminders; Specifications - Sharp R-22GT Operation Manual

1200 watts/1600 watts/1800 watts/2100 watts-heavy duty commercial microwave oven
Hide thumbs Also See for R-22GT:
Table of Contents

Advertisement

REMINDERS

1. Do not operate the oven empty. Either food or water should always be in the oven during operation
to absorb microwave energy.
2. Limit use of metal to those specific examples given in this booklet. Generally, metal should not be used
in the microwave oven during operation.
3. Do not heat eggs in the shell. Pressure will build up inside the shell and it will explode. Do not reheat
cooked eggs unless they are scrambled or chopped. Puncture the yolk before heating eggs.
4. Do not heat oil or fat for deep fat frying.
5. Pierce the "skin" of potatoes, whole squash, apples or any fruit, vegetable or meat with a skin covering
before heating.
6. Use only popcorn packaged in special microwavable packages. Pop using 100% power. Listen
carefully when popping corn. When popping slows to one or two seconds between pops, remove from
oven. Should you ever smell scorching, remove bag from oven immediately.If any unpopped kernels
remain, do not try to re-pop; it may cause a fire.
7. Do not use paper towels, plates or other utensils made from recycled paper for microwave heating.
Recycled paper products may contain certain impurities which could cause the paper to ignite during
microwave heating.

SPECIFICATIONS

AC Line Voltage
Single phase
120V, 60Hz,
A.C. only
AC Power Required
2.0 kW
17.7A
Output Power
1200W
Frequency
2450 MHz
Outside Dimensions
Cavity Dimensions
Weight
Approx. 60 lbs/27 kg Approx. 63 lbs/29 kg Approx. 65 lbs/30 kg Approx. 68 lbs/31 kg
IEC Test Procedure
The International Electrotechnical Commission's standardized method for measuring output wattage.
This test method is widely recognized.
In Compliance with Standards set by
FCC – Federal Communications Commission Authorized.
DHHS – Complies with Department of Health and Human Services (DHHS) rule, CFR,
Title 21 Chapter I, Subchapter J.
– This symbol on the nameplate means the product is certified by
®
NSF International.
– This symbol on the nameplate means the product is listed by
Underwriters Laboratories, Inc.
®
R-22GV/R-22GT
Single phase
230/208V, 60Hz,
A.C. only
2.5 kW
230V-11.9A
208V-13.3A
1600W
2450 MHz
510mm(W) x 470mm(D) x 335mm(H)
330mm(W) x 330mm(D) x 180mm(H)
R-23GT
R-24GT
Single phase
230/208V, 60Hz,
A.C. only
2.9 kW
230V-13.1A
208V-14.6A
1800W
2450 MHz
1
1
20
/
"(W) x 18
/
"(D) x 13
8
2
(including feet)
1
13"(W) x 13"(D) x 7
21
R-25JT
Single phase
230/208V, 60Hz,
A.C. only
3.2 kW
230V-14.5A
208V-15.5A
2100W
2450 MHz
1
/
"(H)
4
/
"(H)
8

Hide quick links:

Advertisement

Table of Contents
loading