Connecting And Setting Up The Reader Using The Pst - Siemens SIMATIC MV540 H Operating Instructions Manual

Optical identification
Hide thumbs Also See for SIMATIC MV540 H:
Table of Contents

Advertisement

Commissioning

7.3 Connecting and setting up the reader using the PST

7.3
Connecting and setting up the reader using the PST
Requirement
The reader has been connected to the power supply via the combination interface and has
started up.
Table 7- 1
Step
1
2
3
4
5
Step 1: Connect the reader and PC using an Ethernet cable
Connect the reader directly to your PC/programming device over an Ethernet cable.
Step 2: Switch on the optical reader
Disconnect the power supply of the optical reader. The optical reader is supplied with power
either via a connected CM cable or via the Power IO RS232 cable or PoE cable. You can
find more detailed information on the connection in the section "Connecting the power supply
(Page 77)".
Note that a self-test is performed each time the optical reader is started. The self-test is
indicated by the power LED flashing and lasts from a few seconds to 2 minutes. Once the
test is completed, the power LED lights up in constant green and the optical reader is ready.
Step 3: Configure the Ethernet connection between reader and PC
To configure the Ethernet connection between the reader and the PC, follow these steps:
1. Open the Primary Setup Tool with "Start > All Programs > Siemens Automation >
SIMATIC > Primary Setup Tool".
2. In the menu bar under "Settings > Set PG/PC interface..." select the network adapter
through which the reader is connected to the PC and confirm with "OK".
3. Start the network search in the "Network > Search" menu.
4. Click on the "+" character beside the folder symbol in the structure tree and click the entry
"Ind. Ethernet interface".
5. To assign the reader a new IP address, activate the "Assign IP parameters" option.
90
Steps for initial commissioning
Activity
Connect the optical reader and PC using an Ethernet cable.
Switch on the optical reader.
Select network adapter.
Configure the Ethernet connection between the optical reader and the PC.
Start Web Based Management (WBM).
Configure the optical reader using the WBM.
Operating Instructions, 06/2018, C79000-G8976-C494-01
SIMATIC MV500

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simatic mv540 sSimatic mv560 x

Table of Contents