Configuring The Scvmm Fabric Workflow - Cisco Nexus 1000V Installing Manual

For microsoft hyper-v
Hide thumbs Also See for Nexus 1000V:
Table of Contents

Advertisement

Chapter 1
Installing the Cisco Nexus 1000V for Microsoft Hyper-V
Create a VLAN inside the Network Segment using the command switchport access vlan <number>,
Step 9
for example, switchport access vlan 100.
Step 10
Associate the Network Segment Pool to the Network Segment using the command member-of network
segment pool <name>, for example, member-of network segment pool IntranetSJ.
Step 11
Import the IP pool template to the Network Segment using the command ip pool import template
<name>, for example, ip pool import template pool10.
Publish the Network Segment using the command publish network segment <name>, for example,
Step 12
publish network segment VMNetworkA. Type exit.
Create a virtual Ethernet port profile of type vethernet using the command port-profile type vethernet
Step 13
<name>, for example, port-profile type vethernet Veth-policy.
Enter the no shutdown command to keep the system in a power-on state. Enter state enabled at the
Step 14
prompt.
Publish the port profile using the command publish port-profile and type exit. The port profile is
Step 15
imported for publishing the Network uplink.
Create a virtual Ethernet port profile of type ethernet using the command port-profile type ethernet
Step 16
<name>, for example, port-profile type ethernet UplinkNoPortChannel.
Enter the no shutdown command to keep the system in a power-on state. Enter state enabled at the
Step 17
prompt.
Create a Network Uplink using the command nsm network uplink NexusUplink.
Step 18
Associate the Network Segment Pool using the command allow network segment pool IntranetSJ, for
Step 19
example, allow network segment pool IntranetSJ.
Import the port profile that was created earlier using the command import port-profile <name>, for
Step 20
example, import port-profile eth-pp-policy.
Step 21
Publish the Network Uplink using the command publish network uplink <name>, for example,
publish network uplink NexusUplink. Type exit.
Copy the running configuration to the start-up configuration using the copy running-config
Step 22
startup-config command. The following message is displayed in the window: Copy complete, now
saving to disk (please wait)
Enter the show running-config command to verify the configuration.
Step 23
The setup script configures the VSM to function in L3 control mode. L2 control mode is not supported
Note
with Cisco Nexus 1000V for Microsoft Hyper-V. When configuring L3 control with Microsoft Hyper-V,
you do not need to create a port profile with capability L3control. The VSM communicates with the
Microsoft Server 2012 management interface directly. There is no need to create a special vEthernet port
profile to be assigned to the Windows 2012 host.

Configuring the SCVMM Fabric Workflow

The entire workflow to configure the SCVMM Fabric Workflow can also be performed using scripts. For
Note
more information, see the
on page
OL-30997-01
"PowerShell Scripts for Configuring the SCVMM Fabric Workflow" section
1-19.