Click OK to finish adding the Virtual Port.
Step 9
Click Next to close the Create Logical Switch Wizard window.
Step 10
Step 11
In the Summary panel, confirm the settings and click Finish. Now the logical switch is created.
The defined configuration is available on every host that uses the logical switch and the hosts, virtual
switches, and virtual machines remain in compliance with their associated logical switch
Note
If you want to add more port profiles to the VSM, you have configure the properties again. All the hosts
should be configured for multiple uplinks. To update the properties and add more uplink port profiles,
right-click the logical switch in the SCVMM user interface and click Properties.
Configuring the VM Network
Once the logical switch and the hosts are configured, complete the following steps to configure the VMs
and associate the network segments to the VMs.
Click VMs and Services in the left navigation panel of the SCVMM user interface.
Step 1
Click VM Networks. Right-click and select the Create VM Network option. The Create VM Network
Step 2
Wizard window opens up.
In the Name panel, specify the name for the VM network in the Name field. Enter the description for
Step 3
the VM network in the Description field. For example, add a name for the VM network as
VM_network. If the name is same as the network-segment name, it is easy for the customers to do the
mapping.
Select the LogicaL Network which is created on the VSM.
Step 4
Step 5
Click Next.
Step 6
To configure VM network in SCVMM 2012 SP1, do the following:
a.
To configure VM network in SCVMM 2012 R2, do the following:
Step 7
a.
b.
OL-30997-01
Click Browse.. in the Port Classification field.
Click Create Port Classification... The Create Port Classification Wizard window opens up.
Enter the name for the port profile classification in the Name field, for example, AllAccess1.
Enter the description for the port profile classification in the Description field.
Assign the selected port profile to a port classification created in the earlier step, that is the All
Access1 in the Select a Port Profile Classification window.
Click OK. Now the selected port classification, AllAccess1 is displayed in the Select a Port
Profile Classification window.
Click OK.
In the Isolation panel, select Specify an externally supplied VM network to configure the isolation
externally. Confirm the External VM Network that was previously created, for example,
VM_Network.
In the Isolation panel, select the Network manager in which is the logical switch was created.
Click Next.