Features

Operations interfaces

...................................................................................................................................................................................................................................
Operations interfaces
The 1643 AM / 1643 AMS offer a wide range of operations interfaces to meet the
needs of an evolving Operations System (OS) network. The operation interfaces
include:
• One Q interface
The Q interface enables network-oriented communication between 1643 AM / 1643
AMS systems and the element/network manager. This interface uses a Qx interface
protocol that is compliant with ITU-T recommendation G.773-CLNS1 to provide
the capability for remote management via the Data Communication Channels
(DCCs). A Q LAN 10BASE-T connector (twisted pair Ethernet, for twisted pair
cables) is used for the Q interface.
• One F interface for a local PC
One RS-232 F-interface is provided, at the connection board of the 1643 AM /
1643 AMS.
This interface provides operation access for a locally installed PC, the Craft
Interface Terminal - ITM-CIT
• User-settable Miscellaneous Discrete Interfaces
The 1643 AM / 1643 AMS provide 4 user-selectable Miscellaneous Discrete Inputs
(MDIs) and 4 outputs (MDOs). The MDIs can be used to read the status of
external alarm points, e.g. power supply detectors, open door detectors or fire alarm
detectors. The MDOs indicate the alarm status of the equipment and drive external
signalling devices. Labels can be associated to an MDI. An MDO can be coupled
to an alarm event.
• Remote SHDSL Power Supply
The 1643 AM / 1643 AMS is also used as a Line Termination Unit (LTU) for third
party Network Termination Units (NTUs). The Remote Power Supply (RPS) unit is
used to power SHDSL Regenerator Units (SRU) that connect third party NTUs to
SHDSL LTUs and can be connected from the MDI/MDO interfaces located on the
NE. For more information about the Remote Power Supply unit, see
SHDSL Power Supply (RPS) Support" (p.
the 1643 AM / 1643 AMSInstallation Guide.
...................................................................................................................................................................................................................................