Technical Data
Battery Charger
Article number
Output voltage
Charging current
Allowable charging temperature
range
Charging time for battery
capacity, approx.
– 1.3–1.5 Ah
– 2.0 Ah
Number of battery cells
Weight according to EPTA-
Procedure 01:2014
Protection class
Operation
Starting Operation
 Observe the mains voltage! The voltage of the power
supply must correspond with the data given on the name-
plate of the battery charger. Battery chargers marked with
230 V can also be operated with 220 V.
Charging Procedure
The charging procedure starts as soon as the mains plug of
the battery charger is plugged into the socket outlet and the
battery 1 is inserted into the charging compartment 2.
Due to the intelligent charging method, the charging condi-
tion of the battery is automatically detected and the battery is
charged with the optimum charging current, depending on
battery temperature and voltage.
This gives longer life to the battery and always leaves it fully
charged when kept in the charger for storage.
Meaning of the Indication Elements
Flashing Green Battery Charge Indicator 4
The rapid-charging procedure is signalled
by a flashing green battery charge indica-
tor 4.
Note: The rapid-charging procedure is only possible when the
battery temperature is within the allowable charging temper-
ature range, see section "Technical Data".
Continuous Lighting of the Green Battery Charge
Indicator 4
Continuous lighting of the green battery
charge indicator 4 indicates that the bat-
tery is fully charged.
Afterwards, the battery can be removed for immediate use.
When the battery is not inserted, continuous lighting of the
battery charge indicator 4 indicates that the mains plug is in-
serted in the socket and that the battery charger is ready for
operation.
Bosch Power Tools
Continuous Lighting of the Red Battery Charge Indicator 3
GAL 1230 CV
1 600 A00 H..
V
12
section "Technical Data". As soon as the allowable charging
A
3.0
temperature range is reached, the battery charger automati-
cally switches to rapid charging.
°C
0 – 45
Flashing Red Battery Charge Indicator 3
(80%)
100%
min
(25)
35
min
(35)
45
3
Troubleshooting – Causes and Corrective
kg
0.46
Measures
/ II
Cause
Flashing red battery charge indicator 3
No charging procedure possible
Battery not (properly)
inserted
Battery contacts
contaminated
Battery pack defective
Battery charge indicators 4 or 3 do not light up
Mains plug of battery charger
not plugged in (properly)
Socket outlet, mains cable or
battery charger defective
Working Advice
With continuous or several repetitive charging cycles without
interruption, the charger can warm up. This is not meaningful
and does not indicate a technical defect of the battery charg-
er.
A significantly reduced working period after charging indi-
cates that the battery is used and must be replaced.
Maintenance and Service
If the replacement of the supply cord is necessary, this has to
be done by Bosch or an authorized Bosch service agent in or-
der to avoid a safety hazard.
English | 5
Continuous lighting of the red battery
charge indicator 3 indicates that the tem-
perature of the battery is not within the al-
lowable charging temperature range, see
A flashing red battery charge indicator 3
indicates a different malfunction of the
charging procedure, see section "Trouble-
shooting – Causes and Corrective Meas-
ures".
Corrective Measure
Properly insert battery into
battery charger
Clean the battery contacts
(e.g. by inserting and remov-
ing the battery several times)
or replace the battery
Replace the battery
Insert mains plug (fully) into
the socket outlet
Check the mains voltage;
have the battery charger
checked by an authorised af-
ter-sales service agent for
Bosch power tools