Parker 8902/RE Technical Manual page 13

Resolver speed feedback options
Hide thumbs Also See for 8902/RE:
Table of Contents

Advertisement

8902/RE Resolver Speed Feedback Option
Parameter Descriptions
TRIP
This information gives the resolver processing state :
-
TRUE : the drive has tripped. Verify the connection of the resolver.
-
FALSE : the system is able to run. The position and speed information are available.
POSITION SET UP
Relative position between the position 0 degree from the resolver and the Parvex
convention for the motor phasing.
Refer to "Motor Phasing" below.
INIT DONE
This information gives the resolver processing init state :
-
TRUE : the resolver processing is running, the init state is completed and the speed
and position information are normally available
-
FALSE : the initialisation phase is on-going. Position and speed information are not
available.
The initialisation phase could be viewed :
-
at power on,
-
after a trip and reset action.
REVERSE CNT DIR
This input allows you to reverse the counting direction of the resolver feedback.
FALSE : counting direction is positive when the motor spins in a clockwise direction,
looking to the front shaft of the motor
TRUE : counting direction is negative when the motor spins in a clockwise direction,
looking to the front shaft of the motor
SPEED FILTER
This input allows you to select the cutting frequency of the first order low pass filter applied
to the resolver speed output.
Range: FALSE-TRUE
Range : - 180° to 180°
Range: FALSE-TRUE
Range: FALSE-TRUE
Range : 10.0 to 1000.0 Hz