Installation Test (Duct Check) - Kenmore 796.6143 Series Use & Care Manual

Table of Contents

Advertisement

INSTALLATION INSTRUCTIONS

INSTALLATION TEST (DUCT CHECK)

Once you have completed the installation of the dryer,
use this test to make sure the condition of the exhaust
system is adequate for proper operation of the dryer.
This test should be performed to alert you to any serious
problems in the exhaust system of your home.
The dryer features Vent, an innovative sensing system that auto-
matically detects blockages and restrictions in dryer ductwork.
Keeping ductwork clean of lint buildup and free of restrictions
allows clothes to dry faster and reduces energy use.
NOTE: The dryer should be cool before starting this test. If the
dryer was warmed up during installation, run the Air Dry cycle
for a few minutes to reduce the interior temperature.
To activate the installation test:
1
Remove the literature and any other contents from inside
the dryer, then close the dryer door.
Do not load anything in the drum for this test, as it may
aff ect the accuracy of the results.
2
Press the Power button, then immediately press and hold
both the Temp and Chime buttons until
the display.
3
Press the START/PAUSE button.
The dryer will start the test, which lasts about 2 minutes.
The heat is turned on and the temperatures in the drum are
measured.
4
Check the display for results.
During the test cycle, monitor the VENT LED on the control
panel. If the LED does not blink by the time the cycle ends,
the exhaust system is adequate. If the exhaust system is
severely restricted, the VENT LED blinks. Have the exhaust
system checked immediately, as dryer performance will be
poor.
Other problems may also be shown with error codes. Refer
to the table below for error code details and solutions.
5
End of cycle.
At the end of the test cycle,
The test cycle ends and the dryer shuts off automatically
after a short delay.
Check any error codes in the chart below before
calling for service.
Error
Code
appears in
tE1
or
tE2
HS
PS
or PF
or nP
26
Not blinking:
Blinking:
OK
RESTRICTED
appears in the display.
Possible Causes
Temperature
Turn off dryer and call for
sensor failure
service.
Humidity sensor
Turn off dryer and call for
failure
service.
• Check power supply or
• Electric dryer
connection of power
power cord is
cord to terminal block.
not connected
Refer to the Connecting
correctly, or
Electric Dryers section of
house power
this guide for complete
supply is
instructions.
incorrect.
• House fuse is
• Reset circuit breaker
blown, circuit
or replace fuse. Do not
breaker has
increase fuse capacity.
tripped, or
If problem is a circuit
power outage
overload, have it
has occurred.
corrected by a qualifi ed
electrician.