ENERGY SAVER OPERATION
During normal operation, the thermostat automatically controls cooling and the fan runs continu-
ously. When the ENERGY SAVER OPERATION is selected, the thermostat automatically
controls cooling and the fan automatically stops when the compressor is not operating. (Fan will
stop 30 seconds after the compressor stops. After the fan stops, the fan is programmed to rotate
for approx. 2 minutes to detect room temperature. This will occur within a 20 min time span.)
NOTE: ENERGY SAVER OPERATION cannot be set during fan only operation.
SLEEP OPERATION
When SLEEP OPERATION is set, the temperature setting is automatically adjusted to prevent the
room from becoming too cold while you sleep. One hour after the SLEEP OPERATION is started,
the temperature setting rises 2°F higher than the original temperature setting. The temperature
will return to its original setting after 8 hours.
NOTE:
• SLEEP OPERATION cannot be set during fan only operation.
• SLEEP OPERATION will be cancelled in 5 seconds, when cooling operation is changed to
fan only operation while SLEEP OPERATION is set.
HOW TO OPERATE
During cooling operation
1
Touch ENERGY SAVER pad.
• ENERGY SAVER indicator will light.
2
To cancel, touch ENERGY SAVER
pad again.
• ENERGY SAVER indicator will go
off.
During cooling operation
1
Press the SLEEP button on the
remote control.
SLEEP
• SLEEP indicator will light.
2
To cancel, press the SLEEP but-
ton again.
• SLEEP indicator will go off.