Absolute Maximum
Maximum voltage on output pin with scanner powered
down.
Maximum current driven into pin from external source.
Parameter Values
Output Low Voltage
Iout = 500uA
Output Low Voltage
Iout = 1mA
Output Low Voltage
Iout = 4mA
Output Low Voltage
Iout = 6mA
Output High Voltage
Iout = -500uA
Output High Voltage
Iout = -1mA
Output High Voltage
Iout = -4mA
Output High Voltage
Iout = -6mA
Vuquest 3320g User Guide
High Value: 6 Volts
High Value: 5mA
High Value: 0.6 Volts
High Value: 0.7 Volts
High Value: 1.0 Volts
High Value: 1.2 Volts
Low Value: 3.6 Volts
Low Value: 3.5 Volts
Low Value: 3.3 Volts
Low Value: 3.1 Volts
External Illumination Control
This allows a pull-up to be connected to this line
provided it does not exceed the current on the
next line of this table while operating.
Maximum current limited by series resistor
dissipation.
Internal one-hundred ohm series resistor drop
included.