41
FF
6A
9999
42
FF
69
9999
43
FF
To program the previous example using specific lengths, you would have to count
any programmed prefixes, suffixes, or formatted characters as part of the length. If
you use the example on
lengths, you would use the following command line:
SEQBLK62001241FF6A001342FF69001243FF
The breakdown of the command line is shown below:
SEQBLK
62
0012
41
FF
6A
0013
42
FF
69
0012
43
FF
54
start character match for Code 39, 41h = "A"
termination string for first code
code identifier for Code 128
code length that must match for Code 128, 9999 = all lengths
start character match for Code 128, 42h = "B"
termination string for second code
code identifier for Code 93
code length that must match for Code 93, 9999 = all lengths
start character match for Code 93, 43h = "C"
termination string for third code
page
53, but assume a <CR> suffix and specific code
sequence editor start command
code identifier for Code 39
A - Code 39 sample length (11) plus CR suffix (1) = 12
start character match for Code 39, 41h = "A"
termination string for first code
code identifier for Code 128
B - Code 128 sample length (12) plus CR suffix (1) = 13
start character match for Code 128, 42h = "B"
termination string for second code
code identifier for Code 93
C - Code 93 sample length (11) plus CR suffix (1) = 12
start character match for Code 93, 43h = "C"
termination string for third code