- Switch the electricity supply ON at the system's main
switch and at the control panel.
- The boiler switches on and the display shows the soft-
ware version of the main control board.
- The display shows the system status and the tempera-
ture measured by the boiler temperature sensor.
- Set the room thermostat to the desired temperature
(20°C).
T
- Press the
key:
- If an outdoor temperature sensor is connected, set
the room temperature setpoint
- If no outdoor temperature sensor is connected, set
the central heating circuit temperature setpoint.
+ -
Press the
keys to adjust the setpoint
Press any of the keys to exit
R T M V
.
The new setting is stored in memory.

INITIAL START-UP