Operating Instructions Contact Clam Only - Lang CSE12-208VCD Installation And Operation Instructions Manual

Electric clamshell grill
Table of Contents

Advertisement

OPERATING INSTRUCTIONS CONTACT CLAM ONLY

1. Turn unit on by placing switch in "ON" position. The "Heat On" indicator, program number and display will flash
indicating unit is heating. When the preset temperature is reached, the heating light, display and program light
indicator will stop flashing followed by 3 beeps. (Initial startup heating time is approximately 30 minutes).
2. Place product on the bottom cooking surface of the unit and close the lids.
3. Press program button and let displayed time count down to "0" at which time unit will beep.
To turn off the beeper, press program button again.
4. Raise lids until it engages into first indent and remove food. Using spatula, scrape residue into grease catcher
tray.
5. Turn the unit off when not in use.
TEMPERATURE/TIMER CONTROLLER OPERATION SPECIFICATIONS
Startup:
1. The preset time will flash until preset temperature is reached.
2. When the control reaches preset temperature, time display, "Heat On" indicator and program indicator will stop
flashing and the alarm will beep three times.
Temperature:
1. To view the actual temperature, press and hold "Temp Button." Display will read "Lo F" if temperature is below
273°F (134°C) and "Hi F" if temperature is above 573°F (301°C).
To Program Time and Temperature:
1. Press and hold "TEMP" (actual temperature displays).
2. While holding "TEMP," press and hold any program button on the Left one second, the LED above the program
number light and the display reads "_ _ _ _." Enter the four-digit security code sequence, 4, 3, 2, 1. The security
code will not show on the display. Once the correct sequence has been entered, the preset time will be displayed
and the LED for that program will begin to flash.
3. Set the time with the "+ or -" buttons.
4. Press the "TEMP" button to save the time.
5. The preset temperature will now be displayed.
6. Set the desired temperature for this program using the "+ or -" buttons.
7. Press the "TEMP" button to save temperature and to exit programming mode for this program. The LED will
stop flashing but will remain lit.
8. Press any other program button within 15 seconds to continue programming without re-entering the security
code.
9. While programming a program (LED is flashing), if no input is received for 15 seconds, the unit will revert to
normal operation and the security code must be re-entered.
Note: Each programming change must be saved by pressing the "TEMP" button!