Young 86004 Instructions Manual

Young 86004 Instructions Manual

Ultrasonic anemometer

Advertisement

Quick Links

METEOROLOGICAL INSTRUMENTS
INSTRUCTIONS
ULTRASONIC ANEMOMETER
MODEL 86004
R.M. YOUNG COMPANY
2801 AERO PARK DRIVE, TRAVERSE CITY, MICHIGAN 49686, USA
TEL: (231) 946-3980
FAX: (231) 946-4772
WEB: www.youngusa.com
PN: 86004-90
REV: G092117

Advertisement

Table of Contents
loading

Summary of Contents for Young 86004

  • Page 1 METEOROLOGICAL INSTRUMENTS INSTRUCTIONS ULTRASONIC ANEMOMETER MODEL 86004 R.M. YOUNG COMPANY 2801 AERO PARK DRIVE, TRAVERSE CITY, MICHIGAN 49686, USA TEL: (231) 946-3980 FAX: (231) 946-4772 WEB: www.youngusa.com PN: 86004-90 REV: G092117...
  • Page 2: Table Of Contents

    OPERATING INSTRUCTIONS Model 86004 Ultrasonic Anemometer Contents SECTION DESCRIPTION PAGE SPECIFICATIONS INTRODUCTION BEFORE INSTALLATION INSTALLATION Placement Mounting and Alignment Wiring Connections OPERATION Analog Outputs With YOUNG Wind Tracker Display Serial Output Formats and Protocols Low Power Operation SETTING SERIAL OUTPUTS AND OPERATING PARAMETERS...
  • Page 4: Specifications

    The sensor features wide operating range, compact size, and easy installation. The 86004 measures wind speed and direction based on the transit time of ultrasonic pulses between three transducers. Measurement results are available as calibrated analog output signals, or serial data using RS-232 or RS-485.
  • Page 5: Installation

    6.0. = Status code Analog VOLTAGE or 4-20mA CURRENT outputs may be = Asterisk (ASCII 42) connected to a datalogger or other device such as a YOUNG 26800 = Checksum Meteorological Translator. See APPENDIX A for connection details. <CR>...
  • Page 6: Low Power Operation

    PARAMETERS SENSOR CONFIGURATION WITH 86SETUP PROGRAM (RECOMMENDED) The YOUNG 86SETUP program is available from the factory web site at www.youngusa.com. It provides an easy method for checking and configuring sensor operation. Install the program on a Windows PC and follow instructions that appear on the program screen to retrieve current sensor settings or send new settings.
  • Page 7: Command Details

    Lower values increase power consumption when SET16n Force analog out (0/1/2=Lo/Mid/Hi) continuous measurements are taken. SET20n 86004 HTR (0/1=Enable/Disable) SET77 SAVE SETTINGS 6.4.11 SET11nn ANALOG DIRECTION SCALE Sets wind direction analog output scale to 0-360 or 0-540 degrees. Go to OPERATE MODE...
  • Page 8: Example Settings

    Liability is limited to repair or replacement of the defective item. A copy 6.4.16 SET16n FORCE ANALOG OUTPUT of the warranty policy may be obtained from R. M. Young Company. This command forces both analog output channels to LO, MID, or HI scale.
  • Page 9: Wiring Connections

    APPENDIX A: WIRING CONNECTIONS 86004-90(G Page 6...
  • Page 10 APPENDIX A: WIRING CONNECTIONS 86004-90(G) Page 7...
  • Page 11 APPENDIX A: WIRING CONNECTIONS 86004-90(G Page 8...
  • Page 12: Sensor Orientation And Dimensions

    275 mm +U m/s "WIND FROM EAST" POST INSERTION 80 mm CARTESIAN 26 mm (U, V) ORIENTATION RING 86004-90(G) R. M. YOUNG COMPANY 2801 Aero Park Drive , Traverse City, Michigan 49686 U.S.A. Page 9 TEL (231) 946-3980 FAX (231) 946-4772...